Enhanced biomechanical outcomes of split-thickness skin grafts with a three-dimensional collagen-elastin matrix in deep second-degree burns: A 12-month comparative study

Nicklas A, Bienger K, Rudari M, Wallner T, Will Marks PA, Dragu A
Plastic & Reconstructive SurgeryDermatologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Background Split-thickness skin grafting (STSG) remains the standard for deep second-degree burns, but grafted skin often shows suboptimal biomechanical properties. The dermal substitute MatriDerm® may improve elasticity, structural integrity, and long-term function. This study evaluated the safety, feasibility, and biomechanical outcomes of a single-stage application of 1 mm MatriDerm® combined with STSG versus STSG alone in lower-extremity burns. Methods In this single-center retrospective cohort study (January 2023-June 2025), 28 patients received 1 mm MatriDerm® with STSG (1:1 mesh, 0.2 mm thickness) and 20 received STSG alone. Standardized 12-month follow-up included Cutometer-based elasticity testing, sebum and temperature measurements, and documentation of surgical outcomes and complications. Results Both treatments were safe and feasible; no re-transplantations, additional surgeries, or deaths occurred. Skin temperature and sebum production did not differ significantly between groups. Cutometer analysis showed clear biomechanical advantages with MatriDerm®: reduced residual deformation under repeated stress (p = 0.0011), improved fatigue resistance (p = 0.002), and a lower viscoelastic ratio (p = 0.00021), indicating greater elasticity. Trends toward improved immediate elasticity and lower initial deformation did not reach statistical significance. Conclusion A single-stage combination of 1 mm MatriDerm® and STSG is safe and enhances biomechanical skin quality compared to STSG alone. Although physiological parameters remain unaffected, improved elasticity and structural resilience suggest a functional benefit. Larger prospective studies with extended follow-up are needed to confirm these findings and assess long-term effects on scar quality and mobility.

Subject terms

Biomechanical Phenomena; Skin Transplantation; Burns; Elastin; Collagen; Feasibility Studies; Lower Extremity; Skin, Artificial; Humans; Male; Female; Middle Aged

DOI: 10.1016/j.burns.2026.107977 · PubMed: 41916203

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Nicklas A, Bienger K, Rudari M, Wallner T, Will Marks PA, Dragu A. Enhanced biomechanical outcomes of split-thickness skin grafts with a three-dimensional collagen-elastin matrix in deep second-degree burns: A 12-month comparative study. Burns. 2026;52(5):107977. doi:10.1016/j.burns.2026.107977

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Plastic & Reconstructive Surgery studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Research · J Plast Reconstr Aesthet Surg · Mar 6, 2026 · Plastic & Reconstructive Surgery, Surgery

The West Australian surgical approach to massive burn injury

Guideline · Burns · Aug 8, 2024 · Plastic & Reconstructive Surgery

Italian burn specialists reached consensus on 24 statements for using Integra dermal regeneration template

Systematic review · Burns · Oct 27, 2025 · Plastic & Reconstructive Surgery, Dermatology

Synthetic matrix associated with longer healing time and higher graft take than bovine-derived matrix

Research · Burns · Nov 20, 2025 · All ages · Plastic & Reconstructive Surgery, Dermatology

Factors affecting skin keratinocyte and fibroblast extraction yields for the production of living skin substitutes to treat severely burned patients

Systematic review · Burns · Feb 25, 2021 · Plastic & Reconstructive Surgery, Dermatology

Systematic review shows wide variation in complications following split-thickness skin graft donor site procedures