Estimation of split renal function using [18F]-flotufolastat PET/CT compared with [68Ga]-PSMA-11 and [99mTc]-MAG3 scintigraphy
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
BACKGROUND: Physiological prostate-specific membrane antigen (PSMA) expression in renal proximal tubules results in radiopharmaceutical uptake in PSMA-PET, suggesting the potential to assess renal function. To evaluate split renal function derived from [18F]F-flotufolastat ([18F]F-rhPSMA-7.3) PET/CT and to systematically compare its performance with [68Ga]Ga-PSMA-11 PET/CT and the reference standard [99mTc]Tc-MAG3 scintigraphy, we retrospectively analyzed 302 patients with metastatic castration-resistant prostate cancer undergoing PSMA-PET/CT using either [18F]F-flotufolastat (n = 221) or [68Ga]Ga-PSMA-11 (n = 81), along with [99mTc]Tc-MAG3 scintigraphy, prior to PSMA radioligand therapy. SRF was calculated from PSMA-PET/CT using mean standardized uptake values and CT-derived renal volumes. SRF was calculated from [99mTc]Tc-MAG3 using standard integral analysis. SRF derived from PSMA-PET/CT ([18F]F-flotufolastat and [68Ga]Ga-PSMA-11) was correlated with split renal function obtained from [99mTc]Tc-MAG3 scintigraphy on a side-specific basis using Pearson correlation and Bland–Altman analysis. Receiver operating characteristic (ROC) analyses were performed to evaluate diagnostic performance for detecting impaired renal function (SRF ≤ 25% and ≤ 40%). A PET-based accumulation index (ACI) was explored in relation to estimated glomerular filtration rate (eGFR) in an exploratory, tracer-specific analysis. RESULTS: Strong correlations were found between PET-SRF and [99mTc]Tc-MAG3-SRF (r = 0.88 for [18F]F-flotufolastat, r = 0.85 for [68Ga]Ga-PSMA-11; both p < 0.0001). Bland–Altman analysis showed a smaller mean bias and narrower limits of agreement for [18F]F-flotufolastat (-0.56%; -11.88% to + 10.75%) compared with [68Ga]Ga-PSMA-11 (-1.18%; -15.3% to + 12.95%), with 92% versus 83% of values within ± 10%, respectively. ROC analysis confirmed excellent accuracy for identifying [99mTc]Tc-MAG3-SRF ≤ 25% (area under the curve [AUC] = 0.997 for [18F]F-flotufolastat; AUC = 0.942 for [68Ga]Ga-PSMA-11). No significant association was observed between ACI and eGFR for either radiopharmaceutical ([18F]F-flotufolastat: Spearman’s ρ = 0.056, p = 0.414; [68Ga]Ga-PSMA-11: Spearman’s ρ = − 0.071, p = 0.536). CONCLUSION: PSMA-PET/CT provides reliable estimates of SRF, with [18F]F-flotufolastat showing slightly superior agreement with [99mTc]Tc-MAG3 scintigraphy. This may potentially eliminate the need for additional renal scintigraphy for SRF assessment in the future and may simplify workflows and reduce patient burden.
Cite this article
Gammel MCM, Olufs C, Hansen K, Brosch-Lenz J, Heck M, Weber WA. Estimation of split renal function using [18F]-flotufolastat PET/CT compared with [68Ga]-PSMA-11 and [99mTc]-MAG3 scintigraphy. EJNMMI Res. 2026. doi:10.1186/s13550-026-01385-0
Spotted a mistake? Suggest a correction
Top studies every Monday
The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.
Get the weekly digest