Visual abstractsVisuals
ResearchJournal of Cardiovascular Magnetic Resonance · Aug 14, 2026

Exercise Cardiovascular Magnetic Resonance Work-Volume Loop Model in Heart Failure with Preserved Ejection Fraction

Ghanbari F, Rodriguez J, Gopal DM, Morales MA, Waxman AB, Manning WJ, et al
Radiology & ImagingCardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Background Heart failure with preserved ejection fraction (HFpEF) is a hemodynamically heterogeneous syndrome including stage C HFpEF (overt) and exercise-induced HFpEF. While impaired compliance reserve is well recognized, contractile reserve remains underexplored. In addition, distinguishing exercise-induced HFpEF from non-cardiac dyspnea (NCD) remains challenging. Exercise cardiovascular magnetic resonance (Ex-CMR) enables quantification of reserve metrics, yet standardizing exercise protocol in dyspneic patients with limited capacity is challenging. This study aimed to establish an analytic framework for deriving non-invasive compliance and contractile reserve metrics independent of fixed exercise thresholds using Ex-CMR, and to evaluate their utility for pathophysiological differentiation among NCD, exercise-induced HFpEF, and stage C HFpEF. Methods We proposed a non-invasive work-volume (W-V) loop model from Ex-CMR using left ventricular end-diastolic (LVEDV) and end-systolic volumes (LVESV) at rest and stress, along with maximum workload during supine cycle ergometer exercise, to construct a trapezoidal loop. The loop's base angles θ₁ and θ₂ represent effort-adjusted compliance and contractile reserve, respectively. In a retrospective analysis of a prospective multi-center Ex-CMR study, these markers were calculated in healthy controls, NCD, exercise-induced HFpEF, and stage C HFpEF groups. Patient cohorts were defined based on invasive hemodynamic exercise-testing thresholds and non-invasive data. ANOVA and post hoc testing were performed. Reproducibility was assessed. Results Among 120 participants (40 healthy controls, 27 NCD, 20 exercise-induced HFpEF, 33 stage C HFpEF), effort-adjusted compliance reserve was impaired in both HFpEF subgroups compared with healthy controls and NCD (p<0.0001). Effort-adjusted contractile reserve was significantly higher in exercise-induced HFpEF than in healthy controls, NCD, and stage C HFpEF (p=0.018, 0.006, and <0.0001, respectively), despite comparable absolute ΔLVESV to NCD and lower ΔLVESV than healthy controls. In contrast, stage C HFpEF demonstrated depressed contractile reserve compared with other groups (p<0.0001). Reproducibility of reserve markers was good to excellent. Conclusions Ex-CMR-derived W-V loop geometry reveals distinctive features across HFpEF subgroups and provides pathophysiological insight from an imaging perspective, demonstrating universal impairment of compliance reserve in HFpEF and a newly identified hypercontractile profile characteristic of exercise-induced HFpEF. Elevated θ₂ in exercise-induced HFpEF may identify a window for intervention before contractile reserve becomes compromised.

DOI: 10.1016/j.jocmr.2026.102785 · PubMed: 42600990

Cite this article

Ghanbari F, Rodriguez J, Gopal DM, Morales MA, Waxman AB, Manning WJ. Exercise Cardiovascular Magnetic Resonance Work-Volume Loop Model in Heart Failure with Preserved Ejection Fraction. J Cardiovasc Magn Reson. 2026. doi:10.1016/j.jocmr.2026.102785

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

Insights Imaging · Nov 20, 2026 · Research · Radiology & Imaging

Integrated system predicts disease-free survival in pancreatic cancer patients better

Eur Radiol Exp · Nov 20, 2026 · Meta-analysis · Radiology & Imaging, Oncology

MRI radiomics of pancreatic tumours: a systematic review of methodological quality and imaging reproducibility

Insights Imaging · Nov 19, 2026 · Research · Radiology & Imaging

Dual-phase photon-counting detector localized parathyroid adenomas with 67.3% to 83.7% sensitivity

EJNMMI Res · Nov 19, 2026 · Research · Radiology & Imaging

Small language model pipeline structures clinical information for dopamine transporter SPECT imaging reports

Insights Imaging · Nov 18, 2026 · Research · Radiology & Imaging

MRI detected placenta accreta spectrum with 100 percent sensitivity