Visual abstractsVisuals
ResearchEuropean Journal of Nuclear Medicine and Molecular Imaging · Feb 2, 2026

Exploratory evaluation of early 68Ga-FAPI-46 PET/CT volume-based parameters in systemic sclerosis-associated interstitial lung disease

Tai SB, Chua WM, Ng CWQ, Noviani M, Tham WP, Saffari SE, et al
Radiology & ImagingAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Purpose Systemic sclerosis-associated interstitial lung disease (SSc-ILD) is a severe complication of SSc, characterised by progressive fibrosis and inflammation. Current diagnostic tools do not accurately differentiate progressors from non-progressors, limiting timely intervention. 68Ga-FAPI-46 is a positron emission tomography (PET) tracer targeting fibroblast activation protein alpha (FAP), a marker of activated fibroblasts, with high affinity and retention. Optimal imaging timepoints and PET parameters for 68Ga-FAPI-46 PET/CT imaging in fibroinflammatory disorders remain undefined. This exploratory study investigated early versus late 68Ga-FAPI-46 PET parameters in evaluating SSc-ILD. Methods Early (10 min) and late (60 min) 68Ga-FAPI-46 PET parameters were compared between progressive (n = 8) and non-progressive SSc-ILD (n = 14), defined by INBUILD trial criteria. PET parameters were correlated with pulmonary function test (PFT) and HRCT parameters. Optimal thresholds for identified PET parameters were determined by closest-to-(0,1) criterion. Results Early total lesion FAPI uptake (median TL-FAPI10min 1245 vs. 714, p = 0.020) and affected lung volume (median AV10min 514 ml vs. 368 ml, p = 0.042) were significantly higher in progressors than non-progressors. Early PET parameters showed stronger, more consistent correlations with PFT and quantitative HRCT parameters than late PET parameters. Volume-based compared to intensity-based PET parameters more consistently correlated with PFT and quantitative HRCT parameters. TL-FAPI10min threshold of 928 had the best diagnostic performance (AUC 0.80). Conclusion This exploratory study showed that 68Ga-FAPI-46 PET/CT imaging, specifically early volume-based PET parameters, was associated with patients with recent disease progression of SSc-ILD. Prospective validation in treatment-response studies is needed to confirm the clinical utility of these PET parameters and their identified preliminary thresholds.

Topics

Humans; Scleroderma, Systemic; Positron Emission Tomography Computed Tomography; Female; Lung Diseases, Interstitial; Male; Middle Aged; Fibroblast Activation Protein Alpha; Endopeptidases; Gallium Radioisotopes; Aged; Time Factors

DOI: 10.1007/s00259-025-07710-4 · PubMed: 41627399

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

Insights Imaging · Nov 20, 2026 · Research · Radiology & Imaging

Integrated system predicts disease-free survival in pancreatic cancer patients better

Insights Imaging · Nov 19, 2026 · Research · Radiology & Imaging

Dual-phase photon-counting detector localized parathyroid adenomas with 67.3% to 83.7% sensitivity

Insights Imaging · Nov 18, 2026 · Research · Radiology & Imaging

MRI detected placenta accreta spectrum with 100 percent sensitivity

Insights Imaging · Nov 18, 2026 · Research · Radiology & Imaging

Classic imaging signs aid diagnosis in head and neck radiology

Insights Imaging · Nov 15, 2026 · Research · Radiology & Imaging

Carotid plaque quantification helps identify patients with obstructive coronary artery disease