Finding Holes: Pathologist-Level Performance Using AI for Cribriform Morphology Detection in Prostate Cancer
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Background
Cribriform morphology in prostate cancer is a histological feature that indicates poor prognosis and contraindicates active surveillance. However, it remains underreported and subject to significant interobserver variability among pathologists. Objective
We aimed to develop and validate an artificial intelligence (AI)-based system to improve cribriform pattern detection. Design setting and participants
We created a deep learning model using an EfficientNetV2-S encoder with multiple instance learning for end-to-end whole-slide classification. The model was trained on 640 digitised prostate core needle biopsies from 430 patients, collected across three cohorts. It was validated internally (261 slides from 171 patients) and externally (266 slides, 104 patients from three independent cohorts). Internal validation cohorts included laboratories or scanners from the development set, while external cohorts used completely independent instruments and laboratories. Annotations were provided by three expert uropathologists with known high concordance. Outcome measurements and statistical analysis
We assessed model performance using the area under the receiver operating characteristic curve (AUC) and Cohen's κ with 95% confidence intervals calculated through bootstrapping. Additionally, we conducted an inter-rater analysis and compared the model's performance against nine expert uropathologists on 88 slides from the internal validation cohort. Results and limitations
The model showed strong internal validation performance (AUC: 0.97, 95% CI: 0.95, 0.99; Cohen's κ: 0.81, 95% CI: 0.72, 0.89) and robust external validation (AUC: 0.90, 95% CI: 0.86, 0.93; Cohen's κ: 0.55, 95% CI: 0.45, 0.64). In our inter-rater analysis, the model achieved the highest average agreement (Cohen's κ: 0.66, 95% CI: 0.57, 0.74), outperforming all nine pathologists whose Cohen's κ ranged from 0.35 to 0.62. Limitations include the retrospective design and that the cross-scanner reproducibility and inter-rater analyses were conducted exclusively on internal validation data, potentially overestimating performance in these analyses. Conclusions
Our AI model demonstrates pathologist-level performance for cribriform morphology detection in prostate cancer. This approach could enhance diagnostic reliability, standardise reporting, and improve treatment decisions for patients with prostate cancer.
Spotted a mistake? Suggest a correction
More in Urology
Checkpoint inhibitor regimens benefit renal cell carcinoma patients with poor prognosis most
Which Patients with Advanced Clear Cell Renal Cell Carcinoma Benefit Most from First-line Checkpoint Inhibitor Combination Regimens: A Meta-analysis of Individual Patient Data and Aggregate Data from Randomised Trials
Male factor infertility is influenced by genetics, environment, and lifestyle choices
Key Determinants and Clinical Impact of Male Factor Infertility: From Etiology to Treatment
Nectin-4-targeted PET/CT compared to FDG PET/CT for urothelial carcinoma staging
Diagnostic Performance of Nectin-4-targeted [68Ga]Ga-DOTA-N188 PET/CT versus [18F]-FDG PET/CT for Staging of Locally Advanced and Metastatic Urothelial Carcinoma: A Prospective, Single-center, Phase 2 Feasibility Trial
Robotic surgery worked as well as open surgery for Wilms tumor in selected cases
Exploring the Limits of Robotic Surgery for Wilms Tumor: A Descriptive Analysis