First Prospective Multicenter Evaluation of Robotic-assisted Partial Nephrectomy Using the DEXTER Robotic Surgery System
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Background and objective
Robot-assisted partial nephrectomy (RAPN) is a standard treatment for small renal tumors due to its precision and nephron-sparing properties. The DEXTER Robotic Surgery System is an open, sterile, compact, three-arm multiport system. This study evaluated the intraoperative and early postoperative safety and clinical performance of DEXTER in RAPN. Methods
A prospective observational study was conducted at two hospitals in France. Seven surgeons performed surgeries using DEXTER. The primary endpoints were major complications (Clavien-Dindo grades III-V) and procedural success rate. The secondary endpoints included perioperative outcomes and 30-d follow-up assessment.Key findings and limitationsThirty-three patients with a median age of 70 yr (interquartile range [IQR] 60-74) and a body mass index of 26.2 kg/m2 (IQR 23.7-31.2) were enrolled. The clampless technique was used in six cases. When full (22 cases) or selective (five cases) clamping was applied, the median warm ischemia time was 20 min (IQR 14-25). All procedures were completed without conversion to open or laparoscopic surgery. Three Clavien-Dindo grade III events occurred. The median estimated blood loss was 300 ml (IQR 100-600), with no blood transfusions. The skin-to-skin operative time was 170 min (IQR 137-200), and the length of hospital stay was 2 d (IQR 2-3). Limitations included the lack of a learning curve assessment due to a low case load per surgeon, and reduced comparability due to a short follow-up time and lack of a control group. Conclusions and clinical implications
RAPN with DEXTER is feasible, and the study supports its short-term safety, even during the initial cases. Further studies are needed to assess its long-term performance. Patient summary
This is a prospective, multicenter cohort study of patients who underwent robot-assisted partial nephrectomy with the DEXTER Robotic Surgery System. During the study, all procedures were completed successfully without any conversions to open or laparoscopic surgery. The results support the short-term safety and feasibility, and highlight the ease of implementation of DEXTER. Further studies are needed to assess its long-term performance.
Spotted a mistake? Suggest a correction
More in Urology
Checkpoint inhibitor regimens benefit renal cell carcinoma patients with poor prognosis most
Which Patients with Advanced Clear Cell Renal Cell Carcinoma Benefit Most from First-line Checkpoint Inhibitor Combination Regimens: A Meta-analysis of Individual Patient Data and Aggregate Data from Randomised Trials
Male factor infertility is influenced by genetics, environment, and lifestyle choices
Key Determinants and Clinical Impact of Male Factor Infertility: From Etiology to Treatment
Nectin-4-targeted PET/CT compared to FDG PET/CT for urothelial carcinoma staging
Diagnostic Performance of Nectin-4-targeted [68Ga]Ga-DOTA-N188 PET/CT versus [18F]-FDG PET/CT for Staging of Locally Advanced and Metastatic Urothelial Carcinoma: A Prospective, Single-center, Phase 2 Feasibility Trial
Robotic surgery worked as well as open surgery for Wilms tumor in selected cases
Exploring the Limits of Robotic Surgery for Wilms Tumor: A Descriptive Analysis