ResearchInsights into Imaging · Apr 16, 2026
Force-controlled robotic ultrasound elastography enhances diagnostic consistency for thyroid nodules
Yan T, Le X, Xie L, Qiu X, Cheng D, Pei C, et al
Abstract
Objective
To assess whether a force-controlled robotic arm can improve image quality, consistency, and diagnostic accuracy of strain elastography (SE) and shear wave elastography (SWE) in differentiating benign from malignant thyroid nodules. Materials and methods
In this prospective study, 131 thyroid nodules were examined by a junior physician, a senior physician, and a robotic arm with a PID-based force feedback system. Image quality was evaluated using the structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), mean squared error (MSE) and mean opinion score (MOS). Consistency was assessed with the Dice similarity coefficient (DSC) and the intraclass correlation coefficient (ICC) for SWE-derived Emax. Diagnostic performance was analyzed via ROC curves and AUC comparisons. Results
The robotic arm achieved higher image quality (SSIM up to 0.94, PSNR 42.25 dB, MSE 3.06) and MOS scores (SE: 4.1 ± 0.3; SWE: 4.3 ± 0.2) than both human operators (all p Conclusion
The force-controlled robotic arm provides standardized, reproducible thyroid elastography with superior quality, consistency, and accuracy compared with manual scanning. Critical relevance statement
This study explores robotic-assisted elastography to improve consistency in thyroid nodule assessment. Key points
The force-controlled robotic arm enhanced ultrasound elastography by generating clearer, more standardized images compared with manual acquisition. The force-controlled robotic arm scanning achieved superior intra-operator reproducibility. Diagnostic performance in differentiating benign from malignant thyroid nodules was significantly improved with robotic elastography, exceeding that of both junior and senior radiologists.
DOI: 10.1186/s13244-025-02181-5 · PubMed: 41989516
Spotted a mistake? Suggest a correction
More in Radiology & Imaging
ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging
Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment
ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging
Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging
ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging
ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging
Classic signs in head and neck imaging-a quick guide for the radiology resident
ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging
Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease