Visual abstractsVisuals
ResearchEuropean Journal of Nuclear Medicine and Molecular Imaging · Aug 1, 2026

From image reconstruction to clinical prognosis: A comprehensive analysis of centiloid-based amyloid PET assessment

Hirschmüller KCE, Prieto E, Guillén EF, Echeveste B, Mínguez F, Romera M, et al
Radiology & ImagingAdult
Read the full paper free at PubMed Central ↗

Abstract

Purpose To investigate the sources of variability in Centiloid (CL) calculations, particularly the influence of image reconstruction and reference region selection, and to examine the relationship between baseline CL scores, visual interpretation and subsequent disease progression. Methods 162 aMCI patients who underwent amyloid PET at a single center were retrospectively analyzed. Visual assessment was performed by two nuclear medicine physicians and Centiloid scoring was determined using syngo.MI Neurology Cortical Analysis, using different reference regions (RR) and image reconstruction settings. The CL values were compared against visual interpretation, using a ROC analysis. The value of CL in predicting the onset of Alzheimer's dementia was assessed. Results The use of the whole cerebellum as RR provided the most robust and consistent CL values across reconstruction methods. The RR was critical in the case of flutemetamol, as CL varied in more than 20 units between pons and whole cerebellum. Visual classifications and CL values showed strong concordance (area under the ROC curve: 0.9786) and the CL cut-off value that maximized agreement with visual reading was 28 CL. During follow-up, 49% of patients progressed to AD dementia and CL-based amyloid positivity was a significant predictor of progression. Conclusion Standardized CL quantification using the whole cerebellum as RR enhances the reliability of amyloid PET interpretation across tracers and reconstruction settings. CL values strongly correlate with visual assessment and are predictive of clinical progression. These findings suggest the potential utility of CL quantification in both clinical and research settings.

Topics

Humans; Positron-Emission Tomography; Female; Male; Prognosis; Image Processing, Computer-Assisted; Amyloid; Retrospective Studies; Aged; Alzheimer Disease; Disease Progression; Aged, 80 and over

DOI: 10.1007/s00259-026-07943-x · PubMed: 42541545

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging

Integrated prognostic system predicts disease-free survival in pancreatic cancer patients

Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment

ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging

Dual-phase photon-counting CT localized parathyroid adenomas with 67.3% to 83.7% sensitivity

Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Advancing placenta accreta spectrum diagnosis: is 3-T MRI or combined MRI with ultrasound the answer?

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Classic imaging signs aid diagnosis in head and neck radiology

Classic signs in head and neck imaging-a quick guide for the radiology resident

ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging

Automated carotid plaque quantification helps identify obstructive coronary artery disease

Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease