Visual abstractsVisuals
ResearchInsights into Imaging · Sep 5, 2026

From zero-shot to fine-tuning: optimize large language models for error detection of ultrasound reports

Lai M, Zhang J, Lv Y, Hou C, Wang C, Li F, et al
Radiology & ImagingAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background High workload and inconsistent quality of ultrasound report writing may lead to diagnostic errors. This study aims to ascertain whether fine-tuned open-source large language models (LLMs) can achieve promising performance for automated quality control of Chinese ultrasound reports, when compared to proprietary LLMs. Materials and methods This retrospective, multi-center study included a multi-subspecialty dataset of 1800 Chinese ultrasound reports, comprising 1500 quality-controlled reports injected artificially with six predefined error types and 300 reports with naturally occurring errors. Nine proprietary LLMs (under zero-shot and few-shot paradigms) and seven open-source LLMs (under fine-tuning) were evaluated, with performance compared against that of radiologists of varying seniority. Performance was measured by detection accuracy, Macro-F1 score, precision, recall, and mean absolute error across six categories. Results Fine-tuned open-source LLMs, notably Qwen3-14B, achieved a detection accuracy of 0.931 and a Macro-F1 of 0.739, approaching the performance of senior radiologists. Some fine-tuned open-source LLMs maintained performance despite smaller parameter sizes and outperformed most proprietary LLMs with vastly larger parameter counts. The fine-tuned Qwen3-14B demonstrated superior recognition capability for semantic errors such as redundancy, spelling, orientation, and unit or value errors. Conclusion This study demonstrates that task-specific fine-tuning enables open-source LLMs to rival proprietary LLMs and expert radiologists in Chinese ultrasound report error detection, offering a locally deployable and privacy-compliant alternative for AI-assisted clinical quality control workflows. Key points Question Can task-specific fine-tuning improve error detection by open-source LLMs in Chinese ultrasound reports and provide an effective approach to automated report quality control? Findings Task-specific fine-tuning enabled open-source LLMs to achieve Macro-F1 scores up to 0.739, approaching that of experienced radiologists (0.764) and outperforming most proprietary LLMs. Critical relevance statement Task-specific fine-tuning allows open-source LLMs to become feasible assistants in ultrasound report quality control workflows, offering a locally deployable, privacy-preserving, and regulation-compliant solution for enhancing reporting consistency and reducing diagnostic errors in high-volume ultrasound examination procedures.

DOI: 10.1186/s13244-026-02394-2 · PubMed: 42701163

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging

Integrated prognostic system predicts disease-free survival in pancreatic cancer patients

Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment

ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging

Dual-phase photon-counting CT localized parathyroid adenomas with 67.3% to 83.7% sensitivity

Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Advancing placenta accreta spectrum diagnosis: is 3-T MRI or combined MRI with ultrasound the answer?

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Classic imaging signs aid diagnosis in head and neck radiology

Classic signs in head and neck imaging-a quick guide for the radiology resident

ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging

Automated carotid plaque quantification helps identify obstructive coronary artery disease

Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease