Visual abstractsVisuals
ResearchEJNMMI Research · May 28, 2026

Fully automatic left ventricle segmentation in [Formula: see text]Rb PET/CT Using a semi-supervised nnU-net

Amirian M, Chevalley A, Asiain MM, Klein R, DeKemp R, Moulton E, et al
Radiology & ImagingAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Quantification of myocardial blood flow (MBF) with [Formula: see text]Rb PET/CT requires accurate delineation of the left ventricle (LV). Manual or semi-automated contouring remains time-consuming and error-prone, particularly in hypoperfused myocardium. We developed and validated a fully automatic LV segmentation pipeline using nnU-Net applied to [Formula: see text]Rb PET/CT. A manual, multimodal segmentation protocol integrating dynamic PET and CT was established in a single-center cohort of 40 non-gated PET/CT series (20 patients, rest & stress), including challenging cases with extensive necrosis (median 21%). The resulting ground truth masks were used for five-fold cross-validation, and semi-supervised learning incorporated 805 additional unlabeled dynamic PET series (504 patients). Model performance was compared with an optimized semi-automatic thresholding baseline (35% [Formula: see text]). Results The nnU-Net significantly outperformed the baseline, achieving a mean Dice of 87.8[85.6, 89.2]% vs 75.1[72.9, 76.9]%, recall 89.1[86.1, 91.4]% vs 82.6[79.1, 85.4]%, and precision 88.1[84.2, 90.4]% vs 70.2[67.2, 73.0]%. The improvement was most pronounced in hypoperfused regions, where recall increased by 20-30% compared to thresholding. Semi-supervised learning modestly enhanced model robustness across both rest and stress acquisitions. Conclusions A deep-learning-based approach enables fully automatic LV segmentation in [Formula: see text]Rb PET/CT with near-expert accuracy. This framework eliminates manual interaction, supports large-scale MBF quantification, and paves the way for reproducible, high-throughput cardiac PET analysis in clinical and research workflows.

DOI: 10.1186/s13550-026-01455-3 · PubMed: 42207374

Cite this article

Amirian M, Chevalley A, Asiain MM, Klein R, DeKemp R, Moulton E. Fully automatic left ventricle segmentation in [Formula: see text]Rb PET/CT Using a semi-supervised nnU-net. EJNMMI Res. 2026. doi:10.1186/s13550-026-01455-3

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

Insights Imaging · Nov 20, 2026 · Research · Radiology & Imaging

Integrated system predicts disease-free survival in pancreatic cancer patients better

Eur Radiol Exp · Nov 20, 2026 · Meta-analysis · Radiology & Imaging, Oncology

MRI radiomics of pancreatic tumours: a systematic review of methodological quality and imaging reproducibility

Insights Imaging · Nov 19, 2026 · Research · Radiology & Imaging

Dual-phase photon-counting detector localized parathyroid adenomas with 67.3% to 83.7% sensitivity

EJNMMI Res · Nov 19, 2026 · Research · Radiology & Imaging

Small language model pipeline structures clinical information for dopamine transporter SPECT imaging reports

Insights Imaging · Nov 18, 2026 · Research · Radiology & Imaging

MRI detected placenta accreta spectrum with 100 percent sensitivity