Visual abstractsVisuals
ResearchEuropean Radiology · Jun 19, 2026

GPT-4.1 and Llama 3.3 70 fail to detect clinically relevant errors in radiology reports in zero-shot evaluation

Akinci D'Antonoli T, Adams LC, Lübberstedt J, Graf MM, Mertens CJ, Busch F, et al
Radiology & ImagingAdult
Read the full paper free at PubMed Central ↗

Abstract

Objectives To evaluate whether GPT-4.1 and Llama 3.3 70B, large language models (LLMs) assessed in zero-shot, baseline configurations, detect and categorize clinically consequential errors across types that range from pattern-based to reasoning-dependent. Materials and methods Two hundred fifty-six radiology reports encompassing CT (n = 104), MRI (n = 104), and X-ray (n = 48) studies across multiple anatomical regions were retrospectively analyzed. For each original report, four variants (n = 1024) were generated, each incorporating one of four predefined error types: E1, anatomical mislabeling that could cause wrong-site actions; E2, physiologically impossible or nonsensical findings; E3, diagnostic inconsistencies that affect staging or diagnosis; E4, inappropriate recommendations. The evaluated models were GPT‑4.1 04-14) and Llama 3.3 70B, both used without domain-specific training or prompt optimization to assess baseline model performance. Results Model performance revealed a systematic hierarchy governed by error type and imaging modality. Physiologically impossible errors (E2) showed the lowest performance: 46.2% (CT) and 33.7% (MRI) for GPT-4.1, compared with 32.7% and 25.0% for Llama 3.3, respectively. Overall success for GPT-4.1 on E2 was 16.3% (CT), 8.7% (MRI), and 12.5% (X-ray). Mislabeling errors (E1) were detected in 49.0% by GPT‑4.1 and 33.7% by Llama 3.3 for MRI. Best performance occurred for inappropriate recommendations (E4), with GPT‑4.1 achieving 85.4% detection in X-ray with high classification accuracy. Conclusion The evaluation framework and benchmark dataset provide a methodology for assessing LLM performance on clinically significant errors. Applied to GPT-4.1 and Llama 3.3 70B in zero-shot settings, the framework reveals a performance gap between pattern-based and reasoning-dependent error detection that warrants investigation across additional models and optimization strategies. Key points Question LLMs are increasingly used for quality assurance of radiology reports, but whether their linguistic competence translates into the detection of clinically significant errors remains unclear. Findings Error detection was type-dependent, both GPT-4.1 and Llama 3.3 70B performed poorly on physiologic and anatomical errors, but better on inappropriate recommendations. Clinical relevance LLMs failed to detect most clinically consequential errors in radiology reports, especially physiologically impossible statements that trained radiologists would rapidly identify.

Topics

Large Language Models; Humans; Diagnostic Errors; Retrospective Studies; Generative Artificial Intelligence; Radiology; Clinical Relevance; Magnetic Resonance Imaging; Tomography, X-Ray Computed

DOI: 10.1007/s00330-026-12697-z · PubMed: 42319406

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

Insights Imaging · Nov 20, 2026 · Research · Radiology & Imaging

Integrated prognostic system predicts disease-free survival in pancreatic cancer patients

Insights Imaging · Nov 19, 2026 · Research · Radiology & Imaging

Dual-phase photon-counting CT localized parathyroid adenomas with 67.3% to 83.7% sensitivity

Insights Imaging · Nov 18, 2026 · Research · Radiology & Imaging

MRI detected placenta accreta spectrum with 100 percent sensitivity

Insights Imaging · Nov 18, 2026 · Research · Radiology & Imaging

Classic imaging signs aid diagnosis in head and neck radiology

Insights Imaging · Nov 15, 2026 · Research · Radiology & Imaging

Carotid plaque quantification helps identify patients with obstructive coronary artery disease