ResearchEuropean Radiology · Feb 20, 2026
Hallucination filtering in radiology vision-language models using discrete semantic entropy
Wienholt P, Caselitz S, Siepmann R, Bruners P, Bressem K, Kuhl C, et al
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Objective
To determine whether using discrete semantic entropy (DSE) to reject questions likely to generate hallucinations can improve the accuracy of black-box vision-language models (VLMs) in radiologic image-based visual question answering (VQA). Materials and methods
This retrospective study evaluated DSE using two publicly available, de-identified datasets: the VQA-Med 2019 benchmark (500 images with clinical questions and short-text answers) and a diagnostic radiology dataset (206 cases: 60 computed tomography scans, 60 magnetic resonance images, 60 radiographs, 26 angiograms) with corresponding ground-truth diagnoses. GPT-4o and GPT-4.1 (Generative Pretrained Transformer) answered each question 15 times using a temperature of 1.0. Baseline accuracy was determined using low-temperature answers (0.1). Meaning-equivalent responses were grouped using bidirectional entailment checks, and DSE was computed from the relative frequencies of the resulting semantic clusters. Accuracy was recalculated after excluding questions with DSE > 0.6 or > 0.3. p values and 95% confidence intervals were obtained using bootstrap resampling and a Bonferroni-corrected threshold of p Results
Across 706 image-question pairs, baseline accuracy was 51.7% for GPT-4o and 54.8% for GPT-4.1. After filtering out high-entropy questions (DSE > 0.3), accuracy on the remaining questions was 76.3% (retained questions: 334/706) for GPT-4o and 63.8% (retained questions: 499/706) for GPT-4.1 (both p Conclusion
DSE enables reliable hallucination detection in black-box VLMs by quantifying semantic inconsistency. This method significantly improves diagnostic answer accuracy and offers a filtering strategy for clinical VLM applications. Key points
Question Can DSE identify hallucination-prone questions and improve the reliability of black-box vision-language models in radiologic image-based VQA? Findings DSE filtering at a 0.3 threshold increased GPT-4o accuracy from 51.7% to 76.3% and GPT-4.1 from 54.8% to 63.8%, while answering fewer questions. Clinical relevance Integrating DSE as a black-box uncertainty filter enables selective answering and explicit uncertainty display for radiology vision-language tools, supporting safer diagnostic use, mitigating hallucinations, and improving clinicians' trust in AI-assisted image interpretation.
Topics
Humans; Entropy; Retrospective Studies; Semantics; Hallucinations; Radiology; Large Language Models; Generative Artificial Intelligence; Magnetic Resonance Imaging
DOI: 10.1007/s00330-026-12384-z · PubMed: 41720937
Spotted a mistake? Suggest a correction
More in Radiology & Imaging
ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging
Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment
ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging
Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging
ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging
ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging
Classic signs in head and neck imaging-a quick guide for the radiology resident
ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging
Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease