Visual abstractsVisuals
ResearchInsights into Imaging · May 27, 2026

How green are large language models for radiology report labelling? Comparing human, rule-based and hybrid workflows

Fink MA, Bischoff A, Atsiatorme E, Kremer A, Kroschke J, Moll M, et al
Radiology & ImagingAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Objectives To address limited quantitative data on sustainable use of large language models (LLMs) in radiology, we quantified the resource footprint of LLMs for labelling CT pulmonary embolism reports and assessed how a hybrid rule-based-LLM workflow changes time, cost and carbon emissions compared with manual labelling. Materials and methods In this single-centre retrospective study, 2923 structured CT reports were labelled using four workflows: a rule-based extractor (RBE), an LLM-only pipeline using 18 open-weight and four proprietary models, a hybrid RBE-LLM pipeline that routed RBE failures to an LLM, and full manual labelling by radiologists. Ground truth was based on radiologist adjudication. For each LLM, we measured per-report latency, estimated CO2 emissions and cost. Radiologists recorded the labelling time per report. Results Manual labelling required 32.8 h for 2923 reports (40.4 s/report; €0.42/report) with 95.0% accuracy (95% CI: 93.7-96.2). LLM-only pipelines were less accurate (85.1%; 95% CI: 84.9-85.5) but reduced labelling time to 12.4 h and cost to €2.60 (both p Conclusion LLM-only labelling reduced labour time and direct costs compared with manual annotation. A hybrid RBE-LLM pipeline that forwards rule-based failures to an LLM concentrated compute where needed and markedly decreased time, cost and emissions, supporting targeted deployment of LLMs for sustainable data-annotation workflows in radiology. Critical relevance By quantifying time, cost and carbon emissions of manual, rule-based, LLM and hybrid report labelling, this study identifies sustainable workflows for deploying LLMs in routine radiology reporting. Key points Manual expert labelling of CT pulmonary embolism reports is time-intensive and costly. Mid-sized LLM configurations provide favourable trade-offs between performance and resource use. Hybrid rule-based-LLM workflows sustain accuracy while reducing resource demands.

DOI: 10.1186/s13244-026-02289-2 · PubMed: 42201579

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging

Integrated prognostic system predicts disease-free survival in pancreatic cancer patients

Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment

ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging

Dual-phase photon-counting CT localized parathyroid adenomas with 67.3% to 83.7% sensitivity

Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Advancing placenta accreta spectrum diagnosis: is 3-T MRI or combined MRI with ultrasound the answer?

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Classic imaging signs aid diagnosis in head and neck radiology

Classic signs in head and neck imaging-a quick guide for the radiology resident

ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging

Automated carotid plaque quantification helps identify obstructive coronary artery disease

Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease