Objectives
To address limited quantitative data on sustainable use of large language models (LLMs) in radiology, we quantified the resource footprint of LLMs for labelling CT pulmonary embolism reports and assessed how a hybrid rule-based-LLM workflow changes time, cost and carbon emissions compared with manual labelling. Materials and methods
In this single-centre retrospective study, 2923 structured CT reports were labelled using four workflows: a rule-based extractor (RBE), an LLM-only pipeline using 18 open-weight and four proprietary models, a hybrid RBE-LLM pipeline that routed RBE failures to an LLM, and full manual labelling by radiologists. Ground truth was based on radiologist adjudication. For each LLM, we measured per-report latency, estimated CO2 emissions and cost. Radiologists recorded the labelling time per report. Results
Manual labelling required 32.8 h for 2923 reports (40.4 s/report; €0.42/report) with 95.0% accuracy (95% CI: 93.7-96.2). LLM-only pipelines were less accurate (85.1%; 95% CI: 84.9-85.5) but reduced labelling time to 12.4 h and cost to €2.60 (both p Conclusion
LLM-only labelling reduced labour time and direct costs compared with manual annotation. A hybrid RBE-LLM pipeline that forwards rule-based failures to an LLM concentrated compute where needed and markedly decreased time, cost and emissions, supporting targeted deployment of LLMs for sustainable data-annotation workflows in radiology. Critical relevance
By quantifying time, cost and carbon emissions of manual, rule-based, LLM and hybrid report labelling, this study identifies sustainable workflows for deploying LLMs in routine radiology reporting. Key points
Manual expert labelling of CT pulmonary embolism reports is time-intensive and costly. Mid-sized LLM configurations provide favourable trade-offs between performance and resource use. Hybrid rule-based-LLM workflows sustain accuracy while reducing resource demands.
DOI: 10.1186/s13244-026-02289-2 · PubMed: 42201579
Spotted a mistake? Suggest a correction
More in Radiology & Imaging
ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging
Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment
ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging
Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging
ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging
ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging
Classic signs in head and neck imaging-a quick guide for the radiology resident
ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging
Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease