Faster-acting insulin aspart showed similar glucose control but less low blood sugar in adults
Hybrid closed-loop glucose control with faster insulin aspart compared with standard insulin aspart in adults with type 1 diabetes: A double-blind, multicentre, multinational, randomized, crossover study
Clinical question: Does faster-acting insulin aspart improve glucose control in hybrid closed-loop systems?
Why it matters: It was unknown if using a faster-acting insulin aspart within a hybrid closed-loop system would change glucose control or hypoglycemia levels compared to standard insulin aspart.
- The study compared 25 adults with type 1 diabetes using a hybrid closed-loop system with either faster-acting insulin aspart or standard insulin aspart over two 8-week periods.
- Time in the target glucose range was 75% ± 8% for both insulin types, though faster-acting insulin was associated with less time below 3.9 mmol/L (2.4% vs. 2.9%).
- There were no differences in mean glucose, glucose variability, total daily insulin requirements, or instances of severe hypoglycemia or ketoacidosis.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Boughton CK, Hartnell S, Thabit H, Poettler T, Herzig D, Wilinska ME. Hybrid closed-loop glucose control with faster insulin aspart compared with standard insulin aspart in adults with type 1 diabetes: A double-blind, multicentre, multinational, randomized, crossover study. Diabetes Obes Metab. 2021. doi:10.1111/dom.14355