ResearchJournal of Heart and Lung Transplantation · Feb 27, 2026

Hybrid durable biventricular assist device implantation with Berlin Heart EXCOR pulsatile RVAD and a continuous flow LVAD

Meyer AL, Bernhardt AM, Garbade J, Eifert S, Schmitto JD, Nozdrzykowski M, et al
Cardiothoracic & Vascular SurgeryCardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗
Top Cardiothoracic & Vascular Surgery studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Abstract

Background Biventricular failure or right ventricular failure (RVF) after continuous-flow left ventricular assist device (cf-LVAD) implantation is associated with high mortality. Durable right ventricular assist device (RVAD) options are limited, particularly for patients with critical cardiogenic shock or late-onset RVF. Use of right-sided cf-LVAD is costly, complex, and off-label. This study explores a hybrid VAD approach, combining a cf-LVAD and a Berlin Heart EXCOR pulsatile RVAD. Methods This multicenter retrospective analysis included patients who received a cf-LVAD with an EXCOR RVAD at six centers in Germany between December 2017 and January 2024. Nineteen patients were analyzed. Baseline demographics, implantation strategy, duration of support, survival, and end-organ function were assessed. Results Among the 19 patients, 73.7% were male, with a median age of 52 years (IQR 30.5-59.5). Seventeen (89.5%) patients initially presented in INTERMACS level 1 and 14 patients underwent stabilization with temporary mechanical circulatory support before durable VAD implantation resulting in a shift to INTERMACS level 3. Simultaneous LVAD and RVAD implantation occurred in 13 (68.4%) patients. Median hybrid support duration was 112 days (range 9 - 1363 days). One-year mortality was 21.1% overall and 14.3% in patients with simultaneous BIVAD implantation. Improved renal and hepatic function was observed, particularly in patients with simultaneous biventricular support. Conclusion Hybrid support using a cf-LVAD with an EXCOR RVAD is a feasible and effective strategy for patients with biventricular failure. This approach demonstrated favorable survival, especially with simultaneous implantation, and was associated with improved end-organ function.

More on this topic

Heart failure

Subject terms

Heart-Assist Devices; Humans; Retrospective Studies; Male; Heart Failure; Female; Middle Aged; Adult; Ventricular Dysfunction, Right; Follow-Up Studies; Germany; Prosthesis Design

DOI: 10.1016/j.healun.2026.02.1674 · PubMed: 41765060

Cite this article

Meyer AL, Bernhardt AM, Garbade J, et al. Hybrid durable biventricular assist device implantation with Berlin Heart EXCOR pulsatile RVAD and a continuous flow LVAD. J Heart Lung Transplant. 2026. doi:10.1016/j.healun.2026.02.1674

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Guideline · Eur J Heart Fail · Jun 10, 2024 · Cardiology, Surgery

ESC consensus outlines strategies to manage right heart failure in LVAD patients

Research · J Heart Lung Transplant · Mar 20, 2026 · Cardiothoracic & Vascular Surgery

Temporary mechanical circulatory support in left ventricular assist device candidates with right ventricular dysfunction: Acuity without long-term futility

Randomized trial · JACC Heart Fail · Dec 18, 2024 · Cardiology

Smaller left ventricle size was associated with lower survival in HeartMate 3 device patients

Review · Circ Res · May 21, 2026 · Cardiology

Right Heart Diastology, Where Are We Now?

Review · Chest · May 22, 2026 · Pulmonology, Cardiology

Managing a Critically Ill Patient With Pulmonary Arterial Hypertension