Smaller left ventricle size was associated with lower survival in HeartMate 3 device patients
Left Ventricular Dimensions and Clinical Outcomes With a Fully Magnetically Levitated Left Ventricular Assist Device
Clinical question: Is a smaller left ventricular end-diastolic diameter associated with clinical outcomes in HeartMate 3 patients?
Why it matters: It was unknown how the size of the left ventricle at the end of a heartbeat relates to survival and adverse events after receiving a HeartMate 3 device.
- Researchers analyzed 1,921 patients receiving a HeartMate 3 mechanical circulatory support device to compare outcomes between those with a left ventricular end-diastolic diameter under 55 mm and those with 55 mm or more.
- Patients with a diameter under 55 mm had a 2-year survival rate of 63.3% compared to 81.8% in the larger diameter group.
- A diameter under 55 mm was associated with higher rates of death from blood compatibility issues, right heart failure, and more frequent hospitalizations due to low-flow alarms.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Topics
Cite this article
Molina EJ, Ahmed MM, Sheikh FH, Cleveland JC, Goldstein DJ, Uriel NY. Left Ventricular Dimensions and Clinical Outcomes With a Fully Magnetically Levitated Left Ventricular Assist Device. JACC Heart Fail. 2024. doi:10.1016/j.jchf.2024.09.019