Is there a difference in venous thrombosis rate in free flap anastomoses based on coupler diameter? A systematic review. Does Size Really Matter?
Key result: Smaller coupler sizes were associated with higher rates of blood clots in tissue flap connections
Systematic review of 11 retrospective case-seriesKey finding
Does coupler diameter affect venous thrombosis rate in free flap anastomoses?
Who
5930
Patients undergoing free flap anastomoses with couplers
Compared
Smaller coupler sizes: 27% (17/62) vs 6.3% (8/126)
Larger coupler sizes: 6.3% (8/126) vs 1.2% (13/1079)
Main outcome
Venous thrombosis rate
Bottom line: Smaller coupler sizes are associated with greater thrombosis rate, but evidence has limitations.
Limitation: Quality score ranged from 2 to 4 and funnel plots indicated publication bias
JPRAS Open · 2021-08-11Download image
Key points
- Researchers analyzed 11 retrospective case-series involving a total of 5930 coupled anastomoses, which are surgical connections used in tissue flap transfers.
- Two studies showed higher thrombosis, or blood clot, rates in smaller sizes: 2.0 mm at 27% versus 3.0 mm at 6.3%, and 1.5 mm at 6.9% versus 3.0 mm at 1.2%.
- Nine of the included studies reported no difference in the rate of blood clots based on the diameter of the coupler device used.
Limitation the authors note: The included studies were retrospective case-series with quality scores ranging from 2 to 4 out of 5 and showed evidence of publication bias.
Discussion prompts
- Would these patients look like yours? Who was left out?
- Is the main outcome one that matters to patients?
- Is the difference large enough to change what you do?
Cite: Krijgh DD, Tellier B, Teunis T, Maarse W, Coert JH. Is there a difference in venous thrombosis rate in free flap anastomoses based on coupler diameter? A systematic review. Does Size Really Matter?. JPRAS Open. 2021. doi:10.1016/j.jpra.2021.07.005
Free full text: PubMed Central · Summary and visual abstract: nowallmed.com/a/is-there-a-difference-in-venous-thrombosis-rate-in-free-flap-lldmy3/ (AI-assisted from the abstract; check the paper before relying on it).