← Back to the study · · Download slide

Journal club handout · JPRAS Open · 2021-08-11

Is there a difference in venous thrombosis rate in free flap anastomoses based on coupler diameter? A systematic review. Does Size Really Matter?

Key result: Smaller coupler sizes were associated with higher rates of blood clots in tissue flap connections

Systematic review of 11 retrospective case-seriesKey finding
Does coupler diameter affect venous thrombosis rate in free flap anastomoses?
Who
5930
Patients undergoing free flap anastomoses with couplers
Compared
Smaller coupler sizes: 27% (17/62) vs 6.3% (8/126)
Larger coupler sizes: 6.3% (8/126) vs 1.2% (13/1079)
Main outcome
Venous thrombosis rate
Bottom line: Smaller coupler sizes are associated with greater thrombosis rate, but evidence has limitations.
Limitation: Quality score ranged from 2 to 4 and funnel plots indicated publication bias
JPRAS Open · 2021-08-11Download image

Key points

Limitation the authors note: The included studies were retrospective case-series with quality scores ranging from 2 to 4 out of 5 and showed evidence of publication bias.

Discussion prompts

  1. Would these patients look like yours? Who was left out?
  2. Is the main outcome one that matters to patients?
  3. Is the difference large enough to change what you do?

Cite: Krijgh DD, Tellier B, Teunis T, Maarse W, Coert JH. Is there a difference in venous thrombosis rate in free flap anastomoses based on coupler diameter? A systematic review. Does Size Really Matter?. JPRAS Open. 2021. doi:10.1016/j.jpra.2021.07.005

Free full text: PubMed Central · Summary and visual abstract: nowallmed.com/a/is-there-a-difference-in-venous-thrombosis-rate-in-free-flap-lldmy3/ (AI-assisted from the abstract; check the paper before relying on it).