Titrating breathing support to diaphragm effort increases time spent in a protective range
Lung- and Diaphragm-Protective Ventilation by Titrating Inspiratory Support to Diaphragm Effort: A Randomized Clinical Trial
Clinical question: Does titrating inspiratory support to diaphragm effort increase time in the diaphragm-protective range?
Why it matters: It is unknown if adjusting mechanical ventilation support based on diaphragm effort can keep breathing effort in a safe range without affecting lung-protective ventilation parameters.
- Researchers studied 40 patients with respiratory failure in an intensive care unit to compare hourly titration of inspiratory support against standard care.
- The intervention group had a median of 81% of breaths in the diaphragm-protective range of 3-12 cm H2O compared to 35% in the control group.
- There were no differences between groups in dynamic transpulmonary pressures or tidal volumes, which were 20.5 ± 7.1 vs 18.5 ± 7.0 cm H2O and 7.56 ± 1.47 vs 7.54 ± 1.22 mL/kg.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
de Vries HJ, Jonkman AH, de Grooth HJ, Duitman JW, Girbes ARJ, Ottenheijm CAC. Lung- and Diaphragm-Protective Ventilation by Titrating Inspiratory Support to Diaphragm Effort: A Randomized Clinical Trial. Crit Care Med. 2022. doi:10.1097/CCM.0000000000005395
Spotted a mistake? Suggest a correction
The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.
Get the weekly digest