Magnetic seeds performed similarly to guidewires for breast cancer localization and lymph node detection
Magnetic Seed vs Guidewire Breast Cancer Localization With Magnetic Lymph Node Detection: A Randomized Clinical Trial
Clinical question: Is a paramagnetic seed equivalent to a guidewire for breast cancer localization and sentinel lymph node detection?
- Researchers randomized 426 women with early breast cancer to receive either a paramagnetic seed or a guidewire for tumor localization and sentinel lymph node detection.
- There were no significant differences in re-excision rates (2.84% for guidewire vs 2.87% for seed) or median resection ratios (1.93 for guidewire vs 2.01 for seed).
- The seed group had more successful localizations (1.9% failure vs 10.1% failure) and shorter median total operative times (69 minutes vs 75.5 minutes).
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Headline, design, result, key points, caveat and citation as plain text.
Cite this article
Pantiora E, Jazrawi A, Hersi AF, et al. Magnetic Seed vs Guidewire Breast Cancer Localization With Magnetic Lymph Node Detection: A Randomized Clinical Trial. JAMA Surg. 2024;159(3):239-246. doi:10.1001/jamasurg.2023.6520