Clinical trialAmerican Journal of Ophthalmology · Jun 12, 2026

Microperimetry as an Outcome Measure Improves Patient Eligibility and Efficacy Detection in RPGR Gene Therapy Trials

Josan AS, Taylor LJ, Raji S, Cehajic-Kapetanovic J, Maclaren RE
OphthalmologyMedical Genetics & GenomicsAdult
Read the full paper free at the publisher ↗
Top Ophthalmology studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Abstract

Purpose To evaluate how primary endpoint selection influences patient eligibility, enrolment, and detection of treatment efficacy in RPGR gene therapy trials, comparing low luminance visual acuity (LLVA) with microperimetry-based outcome measures. Design Retrospective analysis of a phase 1/2 to 3 interventional clinical trial. Subjects Fifteen patients were included in this study. Each was administered with gene therapy in one with the other eye serving as control. Methods Month 12 data from patients with RPGR-associated retinopathy enrolled at a single center in the XIRIUS trial (NCT03116113) were retrospectively analyzed. FDA-aligned low-luminance visual acuity (LLVA) responder criteria (≥15-letter gain) and EMA-aligned significant change from baseline in microperimetry mean sensitivity, were applied. Microperimetry outcomes were evaluated across the full 68-point MAIA grid and within a central 16-point subset. Minimal baseline inclusion thresholds were used. The proportion of gene therapy-treated patients meeting FDA- and EMA-aligned (≥2.5 dB improvement in mean sensitivity) responder criteria was determined. Main outcome measures Proportion of patients meeting the responder criteria in either microperimetry or LLVA. Results At baseline, LLVA excluded more patients from study inclusion due to floor effects than microperimetry. At month 12, 2 of 10 patients (20%) met LLVA responder criteria. In contrast, 5 of 11 patients (45%) met EMA-aligned whole-grid microperimetry responder criteria, including all LLVA responders and 3 additional patients with clear functional improvement not captured by LLVA. Restricting analysis to the central 16 microperimetry points further increased responder detection, identifying 7 of 11 patients (64%). Improvements in microperimetry mean sensitivity of at least 2.5 dB, exceeding expected test-retest variability. No responders were identified for any endpoint in untreated fellow eyes. Conclusions Primary endpoint choice substantially affects efficacy detection and patient inclusion in RPGR gene therapy trials. LLVA demonstrated limited sensitivity and restricted eligibility to a narrow disease window, risking underestimation of treatment benefit. Microperimetry mean sensitivity, particularly when spatially aligned with the treated retinal area, detected functional improvement in a substantially larger proportion of patients and supports broader enrolment. Microperimetry-based endpoints provide a more sensitive and inclusive primary outcome measure for RPGR gene therapy trials.

Subject terms

Humans; Visual Field Tests; Female; Visual Acuity; Genetic Therapy; Retrospective Studies; Visual Fields; Male; Eye Proteins; Retinal Diseases; Patient Selection; Adult

DOI: 10.1016/j.ajo.2026.06.002 · PubMed: 42285469 · Registered: NCT03116113

Cite this article

Josan AS, Taylor LJ, Raji S, Cehajic-Kapetanovic J, Maclaren RE. Microperimetry as an Outcome Measure Improves Patient Eligibility and Efficacy Detection in RPGR Gene Therapy Trials. Am J Ophthalmol. 2026. doi:10.1016/j.ajo.2026.06.002

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Randomized trial · Am J Ophthalmol · Oct 10, 2022 · Ophthalmology

Surgery or medication showed no significant difference in visual field loss for advanced glaucoma

Randomized trial · Am J Ophthalmol · Feb 21, 2023 · Ophthalmology

Combining cataract surgery with a microstent was associated with slower visual field loss

Meta-analysis · Am J Ophthalmol · Mar 21, 2024 · Ophthalmology

Cataract surgery is associated with lower peripheral vision and decreased image quality

Randomized trial · Br J Ophthalmol · Dec 17, 2024 · Ophthalmology, Surgery

Removing the internal limiting membrane during surgery was associated with more retinal blind spots

Randomized trial · Invest Ophthalmol Vis Sci · Jan 15, 2026 · Ophthalmology

Retinal sensitivity decreased with ellipsoid zone and RPE loss in geographic atrophy