ResearchAnnals of Thoracic Surgery · Feb 16, 2026

Mortality and Reintervention After Robotic Mitral Repair in the United States

Tam DY, Razavi AA, Sallam A, Chen Q, Emerson D, Bowdish ME, et al
Cardiothoracic & Vascular SurgeryAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background High-volume centers report acceptable outcomes for robotic mitral repair, yet population-level data are limited. This study compared late mortality and reintervention rates for robotic vs nonrobotic mitral repair in the United States. Methods The Centers for Medicare & Medicaid Services database validated against clinical records was used to identify 26,524 patients with isolated first-time nonemergency mitral repairs with or without tricuspid repairs or ablations without other concomitant procedures. Of these patients, 2227 (8.3%) underwent robotic repair and 24,297 (91.7%) underwent nonrobotic repairs. Propensity score matching was performed on 30 baseline characteristics. The primary end point was a composite of death or mitral reintervention, and the secondary end point was all-cause mortality. Both were compared in a Cox proportional hazards model. Falsification end point analysis assessed for potential unmeasured confounders with death as a competing risk. Results Matching yielded 2226 patient pairs (mean age, 72 years; 44% female; 9% with concomitant tricuspid repair; 7% ablation). Thirty-day mortality did not differ between the groups (1.3% robotic vs 1.3% nonrobotic; P = .90). Robotic repair was associated with lower postoperative atrial fibrillation (19.1% vs 23.2%; P = .001) and a shorter hospital stay (median 5 days [interquartile range, 4-7 days] vs 7 days [interquartile range, 5-9 days]; P < .001). At 5 years, the composite of death or mitral reintervention (17.8% vs 18.6%; hazard ratio, 0.93; 95% CI, 0.79-1.09; P = .37) and all-cause mortality (14.9% vs 15.6%; hazard ratio, 0.93; 95% CI, 0.77-1.11; P = .40) were similar, with falsification testing confirming minimal confounding (P = .20). Conclusions Robotic mitral repair in the United States is safe, yielding outcomes comparable to those of nonrobotic repair.

Subject terms

Humans; Female; United States; Robotic Surgical Procedures; Aged; Male; Reoperation; Mitral Valve; Mitral Valve Insufficiency; Propensity Score; Retrospective Studies; Postoperative Complications

DOI: 10.1016/j.athoracsur.2026.01.049 · PubMed: 41707899

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Tam DY, Razavi AA, Sallam A, et al. Mortality and Reintervention After Robotic Mitral Repair in the United States. Ann Thorac Surg. 2026. doi:10.1016/j.athoracsur.2026.01.049

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Cardiothoracic & Vascular Surgery studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Research · Ann Thorac Surg · Jan 20, 2026 · Cardiothoracic & Vascular Surgery, Cardiology

Durability and Outcomes of Mitral Reintervention After Surgical Mitral Repair in Patients 65 Years and Older in the United States

Research · J Thorac Cardiovasc Surg · Jun 3, 2026 · Cardiothoracic & Vascular Surgery, Cardiology

Impact and outcomes of failure mode after mitral valve repair

Systematic review · Eur J Cardiothorac Surg · Jan 12, 2023 · Cardiothoracic & Vascular Surgery, Cardiology

Alfieri repair had lower reoperation and mitral regurgitation rates than neochordae repair

Research · J Thorac Cardiovasc Surg · Feb 26, 2026 · Cardiothoracic & Vascular Surgery, Cardiology

Microinvasive, off-pump, transventricular neochordae implantation in recurrent mitral valve regurgitation after open heart surgical repair

Research · J Thorac Cardiovasc Surg · Mar 23, 2026 · Cardiothoracic & Vascular Surgery, Cardiology

Impact of reoperation on very long-term survival in patients with failed mitral valve repair: A 30-year single-center Canadian experience