Mortality and Reintervention After Robotic Mitral Repair in the United States
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Background
High-volume centers report acceptable outcomes for robotic mitral repair, yet population-level data are limited. This study compared late mortality and reintervention rates for robotic vs nonrobotic mitral repair in the United States. Methods
The Centers for Medicare & Medicaid Services database validated against clinical records was used to identify 26,524 patients with isolated first-time nonemergency mitral repairs with or without tricuspid repairs or ablations without other concomitant procedures. Of these patients, 2227 (8.3%) underwent robotic repair and 24,297 (91.7%) underwent nonrobotic repairs. Propensity score matching was performed on 30 baseline characteristics. The primary end point was a composite of death or mitral reintervention, and the secondary end point was all-cause mortality. Both were compared in a Cox proportional hazards model. Falsification end point analysis assessed for potential unmeasured confounders with death as a competing risk. Results
Matching yielded 2226 patient pairs (mean age, 72 years; 44% female; 9% with concomitant tricuspid repair; 7% ablation). Thirty-day mortality did not differ between the groups (1.3% robotic vs 1.3% nonrobotic; P = .90). Robotic repair was associated with lower postoperative atrial fibrillation (19.1% vs 23.2%; P = .001) and a shorter hospital stay (median 5 days [interquartile range, 4-7 days] vs 7 days [interquartile range, 5-9 days]; P < .001). At 5 years, the composite of death or mitral reintervention (17.8% vs 18.6%; hazard ratio, 0.93; 95% CI, 0.79-1.09; P = .37) and all-cause mortality (14.9% vs 15.6%; hazard ratio, 0.93; 95% CI, 0.77-1.11; P = .40) were similar, with falsification testing confirming minimal confounding (P = .20). Conclusions
Robotic mitral repair in the United States is safe, yielding outcomes comparable to those of nonrobotic repair.
Subject terms
Headline, design, result, key points, caveat and citation as plain text.
Cite this article
Tam DY, Razavi AA, Sallam A, et al. Mortality and Reintervention After Robotic Mitral Repair in the United States. Ann Thorac Surg. 2026. doi:10.1016/j.athoracsur.2026.01.049
Spotted a mistake? Suggest a correction