ResearchInsights into Imaging · Jul 24, 2026
Multi-component radiological model based on intratumoral CT threshold segmentation for predicting visceral pleural invasion in lung adenocarcinoma ≤ 30 mm
Sun Y, Chen J, Wang T, Zhang L, Xue T, Jin W, et al
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Objectives
This retrospective study aims to investigate the value of intratumoral computed tomography (CT) threshold segmentation in radiomics, deep learning (DL), and radiomics-DL combined models for predicting visceral pleural invasion (VPI) in lung adenocarcinoma (LUAD) ≤ 30 mm. Materials and methods
Patients with invasive LUAD who underwent surgery and had preoperative thin-slice CT scans within four weeks were enrolled from two centers (n = 816). Patients from center 1 were divided into a training set (TS, n = 591) and an internal test set (ITS, n = 98) based on surgical time. Patients from center 2 constituted the external test set (ETS, n = 127). Solid, ground-glass, and peritumoral components were extracted using intratumoral CT threshold segmentation and peritumoral expansion methods. The radiomics model was a Random Forest Classifier; the DL model was a pre-trained Vision Transformer (ViT) fine-tuned on three components; the combined model integrated features from two pipelines. Model performance was evaluated by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. Clinical utility and model interpretability were evaluated using decision curve analysis and SHapley Additive exPlanations (SHAP), respectively. Results
Radiomics, ViT, and radiomics-ViT models achieved AUCs of 0.865, 0.858, and 0.895 in TS; 0.865, 0.844, and 0.852 in ITS; and 0.844, 0.816, and 0.823 in ETS, respectively. Radiomics-ViT model achieved the highest sensitivity, with ViT features contributing the most. Conclusion
A hybrid multi-component feature pipeline could serve as a reliable and highly sensitive tool for VPI prediction in LUAD ≤ 30 mm. Critical relevance statement
The multi-component radiomics-ViT model achieved high sensitivity for VPI prediction in LUAD ≤ 30 mm, which is a promising tool for preoperative treatment design and prognostic assessment. Key points
CT attenuation-defined components remain underexplored in artificial intelligence (AI) models for VPI prediction. Solid, ground-glass, and peritumoral components enable AI models for VPI prediction. Multi-component inputs effectively capture tumor heterogeneity for VPI prediction in LUAD ≤ 30 mm.
DOI: 10.1186/s13244-026-02351-z · PubMed: 42498861
Spotted a mistake? Suggest a correction
More in Radiology & Imaging
ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging
Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment
ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging
Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging
ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging
ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging
Classic signs in head and neck imaging-a quick guide for the radiology resident
ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging
Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease