Visual abstractsVisuals
ResearchThe Lancet Regional Health – Southeast Asia · Mar 6, 2026

Multiple instance learning approach for automated gallbladder cancer detection using ultrasound imaging: multi-center validation of a deep learning model with the public dataset contribution

Gupta P, Bose K, Mudgil P, Dutta N, Gulati A, Prakash G, et al
Radiology & ImagingDigital Health & AIAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Gallbladder cancer (GBC) diagnosis is challenging due to overlapping imaging features. We developed and validated a multiple instance learning (MIL) model for automated GBC detection using a large-scale multi-center ultrasound dataset and benchmarked it against state-of-the-art architectures. Methods This was a retrospective and prospective multi-center cohort study. We trained a gated attention MIL (GAIA-MIL) model on the prospective AURORA-GB dataset (August 2022-July 2024) and two public datasets. The model was evaluated on a temporally independent internal test set (August 2024-December 2024) and three retrospective external cohorts. The area under curve (AUC), sensitivity, and specificity of GAIA-MIL was compared to Clustering-constrained Attention MIL (CLAM), Dual-Stream MIL (DS-MIL), and Transformer-based MIL (TransMIL). Findings The datasets comprised 11,012 images from 1151 patients. Cross-validation achieved a mean AUC of 0.874 (95% CI 0.846-0.902). On the internal test set (n = 97), GAIA-MIL achieved 87.7% sensitivity (78.9-95.1%), 86.2% specificity (72.4-96.9%), and an AUC of 0.883 (0.786-0.963). Pooled external validation (n = 122) showed an AUC of 0.778 (0.698-0.852). Performance varied by external center (AUCs: 0.722, 0.950, and 0.749). In comparative benchmarking, while TransMIL excelled internally (AUC 0.871), its performance degraded significantly in external validation (Pooled AUC 0.654). GAIA-MIL demonstrated superior stability, maintaining robust sensitivity (78.2%), specificity (73.4%), and AUC (0.778) pooled across all diverse external centers where complex transformers struggled. Interpretability analysis confirmed the model focused on clinically relevant features like wall thickening. Interpretation While complex architectures like TransMIL perform well internally, GAIA-MIL offers the optimal balance of performance and generalizability for multi-center deployment. The AURORA-GB benchmark dataset is publicly released to advance research. Funding None.

DOI: 10.1016/j.lansea.2026.100737 · PubMed: 41852453

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging

Integrated prognostic system predicts disease-free survival in pancreatic cancer patients

Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment

ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging

Dual-phase photon-counting CT localized parathyroid adenomas with 67.3% to 83.7% sensitivity

Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Advancing placenta accreta spectrum diagnosis: is 3-T MRI or combined MRI with ultrasound the answer?

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Classic imaging signs aid diagnosis in head and neck radiology

Classic signs in head and neck imaging-a quick guide for the radiology resident

ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging

Automated carotid plaque quantification helps identify obstructive coronary artery disease

Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease