ResearchInvestigative Ophthalmology & Visual Science · Feb 5, 2026

Ocular and General Determinants of Intraocular Pressure: The Two-Continent Eye Study

Jonas JB, Jonas RA, Bikbov MM, Kazakbaeva GM, Iakupova EM, Milea D, et al
OphthalmologyAdult and pediatric

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Purpose The purpose of this study was to assess associations of intraocular pressure (IOP) readings. Methods This was a population-based studies conducted in Russia, China, and India. The project included the population-based investigations of the Beijing Eye Study (BES; n = 3139 participants, age = 40+ years), Ural Eye and Medical Study (UEMS; n = 5514, age = 40+ years), Ural Very Old Study (UVOS; n = 522, age = 85+ years), and Ural Children Eye Study (UCES; n = 4294, age = 6+ years), and Central India Eye and Medical Study (CIEMS; n = 4508, age = 30+ years). Pneumo-tonometry or applanation tonometry were performed. Results The study included 35,199 eyes (17,977 individuals, mean age = 46.9 ± 23.2 years, range = 6-100 years, axial length = 23.2 ± 1.0 mm, range = 18.22-34.20 mm). In the test group (BES, UVOS, and UCES), higher IOP-readings were associated (r2 = 0.37) with younger age, female sex, rural habitation region, higher prevalence of diabetes mellitus, higher systolic blood pressure, thicker central corneal thickness (CCT) and smaller corneal curvature radius (i.e. steeper cornea), longer axial length, lower prevalence of cataract surgery, and higher prevalence of pseudoexfoliation. IOP values, corrected for these associations, correlated with the IOP readings in the external validation groups of UEMS (r2 = 0.85) and CIEMS (r2 = 0.80). In Bland-Altman analysis, the mean bias was 0.80 millimeters of mercury (mm Hg; 95% confidence interval [CI] = 0.76-0.84 or 5.8%, 95% CI = 5.5-6.1) and 1.51 mm Hg (95% CI = 1.47-1.56 or 10.2%, 95% CI = 9.9-10.5), in the UEMS and CIEMS, respectively. The corrected IOP compared to the measured IOP was 8.1 mm Hg lower and 10.0 mm Hg higher, respectively, in 2 clinical examples. A real IOP value of 21 mm Hg corresponded to a measured IOP readings ranging from 29.1 mm Hg to 11.0 mm Hg. Conclusions Among numerous ocular and systemic factors influencing IOP readings (with a relative low correlation coefficient), corneal curvature radius was one of the main ocular determinants. Correction of measured IOP readings led to a large interindividual variation in the upper limit of the "normal" IOP range.

Subject terms

Humans; Intraocular Pressure; Female; Tonometry, Ocular; Aged; Middle Aged; Male; Aged, 80 and over; Adult; India; Child; China

DOI: 10.1167/iovs.67.2.17 · PubMed: 41642027

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Jonas JB, Jonas RA, Bikbov MM, et al. Ocular and General Determinants of Intraocular Pressure: The Two-Continent Eye Study. Invest Ophthalmol Vis Sci. 2026;67(2):17. doi:10.1167/iovs.67.2.17

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Ophthalmology studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Guideline · Invest Ophthalmol Vis Sci · Feb 7, 2022 · Ophthalmology, Cardiology

Experts set minimum standards for mouse models of ocular hypertension

Secondary analysis of a trial n = 92 · Am J Ophthalmol · Jul 17, 2021 · Ophthalmology, Cardiology

Cataract surgery was associated with fewer eye pressure medications and temporary lower pressure levels

Meta-analysis · Am J Ophthalmol · Mar 24, 2023 · Ophthalmology

Beta blockers were associated with lower glaucoma risk and lower eye pressure in meta-analysis

Meta-analysis n = 66 · Am J Ophthalmol · Dec 16, 2023 · Ophthalmology

Supraciliary implant linked to 39.3% IOP drop in glaucoma patients after two years

Randomized trial n = 50 · Am J Ophthalmol · May 14, 2026 · Ophthalmology

Higher volume of peribulbar block solution did not change intraocular pressure levels