Visual abstractsVisuals
ResearchJournal of Plastic, Reconstructive & Aesthetic Surgery · Apr 30, 2026

Optimizing magnetic resonance imaging for detection of greater occipital nerve pathology in migraine headache disorders

Johnson J, Cornely RM, Gutama B, White JK, Gifford R, Thayer M, et al
Plastic & Reconstructive SurgeryAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Background Migraine and occipital headache disorders are increasingly recognized as conditions that may rise from compression of extracranial peripheral nerves, particularly the greater occipital nerve (GON). Despite growing recognition of peripheral mechanisms contributing to headache pathophysiology, objective imaging tools to identify extracranial nerve pathology remain limited. Magnetic resonance neurography has been utilized to evaluate peripheral and extracranial nerves; however, key technical factors that substantially influence image quality - most notably radiofrequency coil selection - have not been systematically characterized. This limitation is especially relevant for small-caliber, superficial extracranial nerves, where diagnostic confidence depends heavily on adequate signal-to-noise ratio and spatial resolution to accurately delineate nerve-vascular relationships. Methods We present a prospective, single-center imaging study evaluating the comparative image quality of MRI surface coils compared to volume coils in visualizing greater occipital nerve pathology in patients undergoing operative intervention for occipital headache disorders. All enrolled participants underwent a non-contrast MRI scan with both volume and surface coils. Images were taken at four anatomical regions of the greater occipital nerve (GON), and signal to noise ratio (SNR) was calculated for each coil with each sequence, at each anatomical landmark. Results Our imaging protocol was completed on three patients (n = 3). SNR measurements of the GON distal to crossing the occipital artery were significantly higher when using the surface coil compared to the volume coil (p = 0.003). On the log transformed scale, the surface coil had more than a two-fold increase in SNR when compared to the volume coil. Conclusion In this pilot imaging study, we demonstrate that the surface coil provides superior image quality and higher SNR when compared to the volume coil for imaging of the extracranial portion of the greater occipital nerve. This serves as a foundational study for developing a specific Magnetic Resonance Neurography (MRN) protocol for diagnosing GON-related headache disorders, and justifies the need for similar studies with a larger cohort.

Topics

Humans; Magnetic Resonance Imaging; Migraine Disorders; Prospective Studies; Female; Adult; Male; Spinal Nerves; Signal-To-Noise Ratio; Middle Aged

DOI: 10.1016/j.bjps.2026.04.021 · PubMed: 42167063

Cite this article

Johnson J, Cornely RM, Gutama B, White JK, Gifford R, Thayer M. Optimizing magnetic resonance imaging for detection of greater occipital nerve pathology in migraine headache disorders. J Plast Reconstr Aesthet Surg. 2026. doi:10.1016/j.bjps.2026.04.021

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Eur Radiol · Dec 22, 2025 · Research · Pediatric · Radiology & Imaging

Neonatal cerebral imaging: feasibility and image quality using an MR-compatible incubator equipped with a 16-channel head coil

Eur Radiol · Apr 2, 2026 · Research · Pediatric · Radiology & Imaging

Deep learning improves image quality in motion-robust and sedation-free pediatric brain MRI

Pain · Dec 19, 2025 · Research · Anesthesiology

Spontaneous activity in pain patient stem cell-derived sensory neurons arises from one functional subclass

Otolaryngol Head Neck Surg · May 20, 2026 · Research · Pediatric · ENT (Otolaryngology)

Longitudinal Evaluation of Otoacoustic Emissions as a Screening Tool for High-Frequency Hearing Loss in Adolescents

Eur Radiol · Jun 3, 2026 · Research · Radiology & Imaging

Virtual non-contrast images from dual-layer spectral CT: comparison with true non-contrast across abdominal structures