Organ-specific malperfusion rates and mortality in acute type A aortic dissection meta-analysis
Organ-specific malperfusion in acute type A aortic dissection: epidemiological meta-analysis of incidence rates
Clinical question: What is the incidence and mortality of organ-specific malperfusion in acute type A aortic dissection?
Why it matters: The incidence and survival impact of specific organ-related blood flow issues in acute type A aortic dissection are not clearly defined.
- Researchers analyzed 40 studies involving 35 361 patients to determine the incidence and mortality of organ-specific malperfusion, which is inadequate blood flow to organs, in acute type A aortic dissection.
- Peripheral limb malperfusion was the most common at 12% (95% c.i. 10 to 14), while spinal malperfusion was the least common at 1% (95% c.i. 1 to 2).
- In-hospital mortality rates for patients with malperfusion ranged from 18% to 36%, with the highest rates seen in mesenteric malperfusion at 36% (95% c.i. 28 to 45).
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Topics
Cite this article
Chandiramani A, Al-Tawil M, Elleithy A, Kakar S, Rajasekar T, Panda A. Organ-specific malperfusion in acute type A aortic dissection: epidemiological meta-analysis of incidence rates. BJS Open. 2025. doi:10.1093/bjsopen/zrae146