Oxygenated machine perfusion after cold storage did not improve one-year kidney graft survival
Oxygenated End-Hypothermic Machine Perfusion in Expanded Criteria Donor Kidney Transplant: A Randomized Clinical Trial
Clinical question: Does oxygenated hypothermic machine perfusion after static cold storage improve 1-year graft survival?
Why it matters: It was unknown if adding short-term oxygenated machine perfusion after static cold storage improves one-year graft survival in kidneys from expanded criteria donors.
- Researchers conducted a multicenter trial of 305 kidneys from expanded criteria donors, comparing static cold storage alone to static cold storage followed by oxygenated machine perfusion.
- One-year graft survival was 92.1% in the oxygenated machine perfusion group versus 93.3% in the static cold storage group, which was not a statistically significant difference.
- No significant differences were found between the two groups for delayed graft function, primary nonfunction, kidney filtration rate, or acute rejection.
Limitation the authors note: The study was underpowered because of the high overall graft survival rate.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Husen P, Boffa C, Jochmans I, Krikke C, Davies L, Mazilescu L. Oxygenated End-Hypothermic Machine Perfusion in Expanded Criteria Donor Kidney Transplant: A Randomized Clinical Trial. JAMA Surg. 2021. doi:10.1001/jamasurg.2021.0949
Spotted a mistake? Suggest a correction
The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.
Get the weekly digest