Visual abstractsVisuals
ResearchJournal of the National Cancer Institute · Jan 7, 2026

Performance of multiple multi-cancer detection tests using a large independent reference set (Alliance A212102)

Wood ME, Pinsky PF, Novotny PJ, Leevan E, Weiss M, Edelman DC, et al
OncologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Reference sets are needed to evaluate performance of multi-cancer detection (MCD) assays. The National Cancer Institute funded the Alliance reference set study to assess MCDs for use in future trials. Methods Individuals with cancer and controls were recruited; blood specimens were collected prior to cancer treatment. A performance evaluation study was designed utilizing reference set samples. Companies (n = 6) were selected to participate based on review of performance data and ability to utilize the blood collection tube. Companies received samples from cancer types their assay was designed to detect ("targeted"), plus additional "non-targeted" and control samples. Companies reported positive/negative calls, risk scores, and tissue-of-origin (TOO) predictions. Sensitivity was computed for early (I-II) and late (III-IV) stage cases, based on positive/negative calls (SEPN) and at fixed 98% specificity (SE98). Specificity and TOO accuracy were computed. Results Five hundred and forty nine cases (encompassing 13 cancer types) and 413 controls from the reference set were included in the study. Companies assessed samples from median 6 (range 5-9) targeted cancer types and median 8 (range: 7-11) overall cancer types. Median (range) specificity was 92.3% (76.5%-98.5%). Median (range) SEPN was 32% (25%-42%) for early stage and 73% (48%-89%) for late stage; while median (range) SE98 was 19% (8%-35%) for early stage and 66% (13%-79%) for late stage. Median sensitivity for non-targeted types was 40% (early stage) and 52% (late stage). Median (range) TOO accuracy (primary predicted site) was 75% (64%-78%). Conclusions Sensitivity and specificity varied widely across assays with early-stage sensitivity substantially lower than late-stage sensitivity. Clinical trial registration number ClinicalTrials.gov identifier NCT05334069.

Topics

Aged; Female; Humans; Male; Middle Aged; Biomarkers, Tumor; Case-Control Studies; Early Detection of Cancer; National Cancer Institute (U.S.); Neoplasms; Reference Standards; Sensitivity and Specificity

DOI: 10.1093/jnci/djag001 · PubMed: 41499420 · Registered: NCT05334069

Spotted a mistake? Suggest a correction

More in Oncology

Randomized trialVisual abstractLancet Oncol · Nov 20, 2026 · Oncology

Prostate and pelvic node radiotherapy increased gastrointestinal adverse events by 6.7 percentage points

Prostate and pelvic nodal stereotactic body radiotherapy (SBRT) versus prostate-only SBRT for high-risk, localised prostate cancer (PACE-NODES): early adverse event results from an international, open-label, phase 3, randomised controlled trial

ResearchJAMA Oncol · Nov 19, 2026 · Oncology

Computed Tomography Beyond 5 Years Associated With Lower Mortality Rate

Chest Computed Tomography Receipt Beyond 5 Years After Lung Cancer Diagnosis and Survival

ResearchJ Immunother Cancer · Nov 19, 2026 · Oncology

CD8+ T cell-derived IFN-γ drives PD-1 immunotherapy efficacy alone

Only CD8+ T cell-derived IFN-γ is required to drive PD-1 immunotherapy efficacy

ResearchJNCI Cancer Spectr · Nov 19, 2026 · Oncology

HIV stigma linked to lower quality cancer care for people with HIV and cancer

HIV stigma, discrimination, and care quality among PWH and cancer at an NCI-designated comprehensive cancer center

ReviewCancer Commun · Nov 19, 2026 · Oncology

Brain metastasis development involves complex interactions between tumor cells and microenvironment

Unraveling the Shaping of the Microenvironment in Brain Metastasis: From Dissemination to Overt Lesions