← Back to the study · · Download slide

Journal club handout · Eur J Cardiothorac Surg · 2023-05-26

Perioperative neuromonitoring during thoracoabdominal aortic aneurysm open repair: a systematic review

Key result: Neuromonitoring techniques are used to manage spinal cord blood flow during aortic aneurysm surgery

Systematic reviewBenefit found
What are the effects and practices of neuromonitoring during open thoracoabdominal aortic aneurysm repair?
Who
3130
Patients undergoing open thoracoabdominal aortic aneurysm repair
Compared
Motor-evoked potentials
Somatosensory-evoked potentials
Main outcome
Postoperative spinal cord ischaemia
Bottom line: Simultaneous motor-evoked potentials and somatosensory-evoked potentials monitoring is a reliable method to detect findings and direct protective manoeuvres.
Eur J Cardiothorac Surg · 2023-05-26 · Save PNG

Key points

Discussion prompts

  1. Would these patients look like yours? Who was left out?
  2. Is the main outcome one that matters to patients?
  3. Is the difference large enough to change what you do?

Cite: Sef D, Thet MS, Miskolczi S, et al. Perioperative neuromonitoring during thoracoabdominal aortic aneurysm open repair: a systematic review. Eur J Cardiothorac Surg. 2023;63(6). doi:10.1093/ejcts/ezad221

Free full text: Eur J Cardiothorac Surg website · Summary and visual abstract: nowallmed.com/a/perioperative-neuromonitoring-during-thoracoabdominal-aortic-aneurysm-lqpnlv/ (AI-assisted from the abstract; check the paper before relying on it).