One hour troponin testing protocol showed no difference in safe discharges compared to three hour care
Rapid Acute Coronary Syndrome Evaluation Over One Hour With High-Sensitivity Cardiac Troponin I: A United States-Based Stepped-Wedge, Randomized Trial
Stepped-wedge, randomized trialNo clear difference
Is a 0/1-hour accelerated protocol effective for myocardial infarction exclusion compared to standard care?
Who
32609
Patients evaluated for possible myocardial infarction in emergency departments · 9 emergency departments in the United States
Compared
59.5%Standard care protocol
57.8%Accelerated protocol
Main outcome
Proportion of patients discharged without 30-day death or myocardial infarction
Result: adjusted odds ratio 1.05 (95% CI 0.95 to 1.16)
Bottom line: A 0/1-hour accelerated protocol did not lead to more safe emergency department discharges compared with standard care.
Ann Emerg Med · 2024-06-15Download image
Clinical question: Is a 0/1-hour accelerated protocol effective for myocardial infarction exclusion compared to standard care?
Key points
- Researchers studied 32,609 patients across 9 emergency departments to compare a 0/1-hour accelerated protocol to a 0/3-hour standard care protocol for heart attack evaluation.
- The proportion of safe discharges was 59.5% in the standard care group and 57.8% in the accelerated protocol group, which was not a significant difference.
- At 30 days, there were 38 (0.4%) deaths or heart attacks in the standard care group and 52 (0.4%) in the accelerated protocol group.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Miller J, Cook B, Gandolfo C, et al. Rapid Acute Coronary Syndrome Evaluation Over One Hour With High-Sensitivity Cardiac Troponin I: A United States-Based Stepped-Wedge, Randomized Trial. Ann Emerg Med. 2024. doi:10.1016/j.annemergmed.2024.04.024
Spotted a mistake? Suggest a correction