Rapid ADAMTS13 activity assays for thrombotic thrombocytopenic purpura: a systematic review and meta-analysis
Key result: Rapid ADAMTS13 activity assays accurately diagnose thrombotic thrombocytopenic purpura
Systematic review and meta-analysisBenefit found
How do rapid ADAMTS13 activity assays perform relative to reference standard assays?
Who
4207
Patient samples with suspected or confirmed thrombotic thrombocytopenic purpura
Compared
HemosIL AcuStar chemiluminescence immunoassay: sensitivity 0.98
Technofluor fluorescence resonance energy transfer: sensitivity 0.93
Technoscreen assay: sensitivity 0.98
Main outcome
performance characteristics relative to reference standard assays
Bottom line: Rapid assays, especially HemosIL AcuStar, show high sensitivity and specificity for diagnosing thrombotic thrombocytopenic purpura.
Blood · 2025-04-21Download image
Key points
- Nineteen studies with 4207 patient samples compared rapid ADAMTS13 assays to reference standard assays.
- The HemosIL AcuStar assay had 0.98 sensitivity and 0.99 specificity for diagnosing TTP.
- Rapid assays can help avert unnecessary empiric treatment in patients without TTP.
Why it matters: Reference standard assays have long turnaround times, leading to empiric treatment of many non-TTP patients
Discussion prompts
- Would these patients look like yours? Who was left out?
- Is the main outcome one that matters to patients?
- Is the difference large enough to change what you do?
Cite: Deshpande SR, Tarawneh H, Deitelzweig C, et al. Rapid ADAMTS13 activity assays for thrombotic thrombocytopenic purpura: a systematic review and meta-analysis. Blood. 2025. doi:10.1182/blood.2025028416
Free full text: PubMed Central · Summary and visual abstract: nowallmed.com/a/rapid-adamts13-activity-assays-for-thrombotic-thrombocytopenic-1s5m3kb/ (AI-assisted from the abstract; check the paper before relying on it).