Clinical question: How does real-world Afirma Genomic Sequencing Classifier performance compare to the validation study?
Why it matters: It was unknown if the Afirma genomic sequencing classifier performs as well in real-world clinical settings as it did in its original validation study.
Key points
Researchers performed a meta-analysis of 13 independent real-world studies to compare Afirma genomic sequencing classifier performance against its 2018 validation study.
Real-world observed specificity was 88% and observed positive predictive value was 65%, which were significantly higher than the validation study metrics.
The real-world benign call rate was 67%, compared to 54% in the validation study.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Nasr CE, Andrioli M, Endo M, Harrell RM, Livhits MJ, Osakwe I. Real-World Performance of the Afirma Genomic Sequencing Classifier (GSC)-A Meta-analysis. J Clin Endocrinol Metab. 2022. doi:10.1210/clinem/dgac688