Visual abstractsVisuals
ResearchEuropean Journal of Nuclear Medicine and Molecular Imaging · Jul 1, 2026

Redefining robotic image-guidance - tomographic visualization of lesions during prostate cancer surgery via gantry-free robotic SPECT

Berrens AC, Pirkovets K, Azargoshasb S, Slof LJ, Cakal BA, van Leeuwen PJ, et al
Radiology & ImagingAdult
Read the full paper free at PubMed Central ↗

Abstract

Purpose The introduction of the drop-in gamma probe has advanced intraoperative molecular imaging during prostate cancer surgery. We have been able to convert the sensor's numeric readout to tomographic images, so-called robotic-SPECT (RoboSPECT) and investigate how this is impacted by radiopharmaceutical avidities and drop-in scan metrics. Methods The gamma sensor readout was registered with its 3D position and orientation, allowing a custom reconstruction algorithm to generate RoboSPECT images. Evaluations occurred in 21 patients; 10 sentinel node procedures (SN; primary prostate cancer) and 11 PSMA-radioguided surgery (recurrent prostate cancer). RoboSPECT findings were related to respective pre- and intra-operative controls, including preoperative PSMA-PET/CT and/or SPECT/CT images and fluorescence detection (SN only). Results RoboSPECT proved to be safe and applicable in a range of conditions. In the SN-group, 26 SN-SPECT/CT lesions were successfully identified with SN-RoboSPECT (100%); 3 were tumor positive (sensitivity 100%). Only 73% of SNs were surgically visible with fluorescence imaging. For the PSMA guided group, the 14 lesions identified on PSMA-PET/CT were all visualized with PSMA-RoboSPECT (100%); 18 specimens were tumor positive (sensitivity 78% for both PSMA-PET/CT and PSMA-RoboSPECT). Preoperative PSMA-SPECT/CT only identified 4 PSMA-lesions (29%). No false positives were seen for roboSPECT and all final resection margins were clean. At 6-months 0% of the SN-patients and 20% of PSMA-patients showed biochemical recurrence. Conclusion RoboSPECT provides 3D context that extends the utility of drop-in gamma tracing and assists the alignment between pre- and intra-operative target perception. Here SN-RoboSPECT clearly outperformed fluorescence SN imaging and PSMA-RoboSPECT outperformed preoperative PSMA-SPECT/CT imaging.

Topics

Humans; Male; Prostatic Neoplasms; Surgery, Computer-Assisted; Robotic Surgical Procedures; Tomography, Emission-Computed, Single-Photon; Aged; Single Photon Emission Computed Tomography Computed Tomography; Middle Aged

DOI: 10.1007/s00259-026-07987-z · PubMed: 42384203

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging

Integrated prognostic system predicts disease-free survival in pancreatic cancer patients

Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment

ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging

Dual-phase photon-counting CT localized parathyroid adenomas with 67.3% to 83.7% sensitivity

Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Advancing placenta accreta spectrum diagnosis: is 3-T MRI or combined MRI with ultrasound the answer?

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Classic imaging signs aid diagnosis in head and neck radiology

Classic signs in head and neck imaging-a quick guide for the radiology resident

ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging

Automated carotid plaque quantification helps identify obstructive coronary artery disease

Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease