Visual abstractsVisuals
ResearchUltrasound in Obstetrics & Gynecology · Jan 7, 2026

Reference charts for first-trimester placental three-dimensional fractional moving blood volume derived using OxNNet

Mathewlynn S, Starck LN, Yin Y, Soltaninejad M, Swinburne M, Nicolaides KH, et al
Obstetrics & GynecologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Objective To establish a comprehensive reference range for first-trimester placental three-dimensional (3D) single-vessel fractional moving blood volume (svFMBV) using the OxNNet toolkit, based on values observed in healthy pregnancies. Methods This study utilized data from the First-trimester Placental Ultrasound (FirstPLUS) study, a longitudinal observational cohort study conducted between March and November 2022 at King's College Hospital, London, UK. Participants underwent 3D ultrasound assessment of the placenta, including power Doppler imaging, during routine first-trimester screening. The OxNNet toolkit was used for automated placental segmentation and 3D-svFMBV calculation. Quality control was performed in three stages to ensure image completeness and segmentation accuracy. Quantile regression and lambda-mu-sigma (LMS) modeling were used to construct reference charts for 3D-svFMBV. Model fit was assessed using the Akaike information criterion, and centile curves were constructed. Results The final cohort comprised 2547 cases. Visual assessment of histograms and quantile-quantile plots revealed positive skew in 3D-svFMBV determined at five specific locations within the uteroplacental vasculature. LMS modeling provided the best fit for constructing centile charts, with the Box-Cox Power Exponential original distribution used in most cases. The resulting centile charts demonstrated close agreement between predicted and observed centiles, with minimal deviation across all target centiles. Conclusions This study provides novel reference ranges for first-trimester placental 3D-svFMBV at five locations within the uteroplacental vasculature. These findings offer a valuable foundation for future research into placental function and pregnancy outcome. © 2026 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

Topics

Humans; Female; Pregnancy; Pregnancy Trimester, First; Reference Values; Ultrasonography, Prenatal; Placenta; Adult; Imaging, Three-Dimensional; Blood Volume; Longitudinal Studies; Ultrasonography, Doppler

DOI: 10.1002/uog.70161 · PubMed: 41499517

Spotted a mistake? Suggest a correction

More in Obstetrics & Gynecology

ResearchAJOG · Nov 20, 2026 · Obstetrics & Gynecology

Biomechanical principles may help reduce pelvic floor injuries during vaginal birth

Biomechanical Insights for Reducing Pelvic Floor Injuries during Vaginal Birth

Randomized trialVisual abstractBMJ · Nov 18, 2026 · Obstetrics & Gynecology

No increase in spontaneous vaginal births with hyoscine butylbromide or sodium bicarbonate

Effect of intrapartum hyoscine butylbromide and sodium bicarbonate on spontaneous vaginal birth in nulliparous women after induction of labour (SAINT): multicentre randomised placebo controlled factorial trial

ResearchBMC Med · Nov 16, 2026 · Obstetrics & Gynecology, Pediatrics

Asthma treatment during pregnancy linked to higher odds of small gestational age

Treated and untreated maternal asthma and early pregnancy outcomes: a retrospective cohort study of 324,238 infants

ResearchBMC Med · Nov 16, 2026 · Obstetrics & Gynecology

Reduced DHS data availability affects global maternal mortality estimates significantly

The future of maternal mortality measurement: implications of reduced DHS availability

ReviewFertil Steril · Nov 15, 2026 · Obstetrics & Gynecology

Adenomyosis management in women seeking pregnancy remains uncertain

The challenge of Adenomyosis across the ART journey: insights from the Naples Workshop group