Visual abstractsVisuals
ResearchJournal of Cardiovascular Magnetic Resonance · Jun 4, 2026

Reference ranges for myocardial native T1, T2, and extracellular volume at 5.0T cardiac magnetic resonance imaging in healthy adults

Wang S, Qian X, Wu Y, Miao X, Guan Z, Wang D, et al
Radiology & ImagingCardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background A 5.0T Cardiovascular magnetic resonance (CMR) offers potential advantages over 3.0T systems, including improved signal-to-noise ratio and spatial resolution. Although myocardial T1 and T2 mapping techniques are increasingly applied in clinical practice, reference ranges for these parameters at 5.0T have not yet been established. The aim of this study is to determine normal reference values for myocardial native T1, T2 relaxation times, and extracellular volume fraction (ECV) in healthy adults using 5.0T CMR. Methods This prospective study enrolled 181 healthy Chinese adults aged 20-80 years who underwent 5.0T CMR. T1 and T2 mapping of the left ventricle were performed using a motion-corrected modified Look-Locker inversion recovery sequence and a T2-prepared single-shot sequence, respectively. Global and segmental myocardial T1, T2, and ECV values were quantified. Associations with sex, age, body mass index (BMI), and myocardial thickness were analyzed. Results The mean global myocardial T1, T2, and ECV values were 1496 ± 37 ms, 35 ± 3 ms and 27 ± 2 %, respectively. Females showed significantly higher T1 and T2 values than males (T1: 1509 ± 35 ms vs 1483 ± 35 ms, p<.001; T2: 36 ± 2 ms vs 34 ± 2 ms, p<.001). No significant age-related differences were observed. T1, T2, and ECV values were inversely associated with BMI (T1: r=-0.16, p=.034; T2: r=-0.35, p<.001; ECV: r=-0.31, p=.015). T1 values positively correlated with myocardial thickness (r=0.19, p<.001), whereas T2 and ECV values negatively correlated with thickness (r=-0.21 and -0.19, respectively; both p<.001). Segmental analysis showed lower T1 but higher T2 and ECV values at the apex compared with the mid and basal myocardium (all p<.001). Conclusion This study establishes normative myocardial T1, T2, and ECV values at 5.0T CMR in healthy adults. Myocardial tissue characteristics were influenced by sex, BMI, and myocardial thickness, with regional variations observed across myocardial segments.

DOI: 10.1016/j.jocmr.2026.102753 · PubMed: 42248302

Cite this article

Wang S, Qian X, Wu Y, Miao X, Guan Z, Wang D. Reference ranges for myocardial native T1, T2, and extracellular volume at 5.0T cardiac magnetic resonance imaging in healthy adults. J Cardiovasc Magn Reson. 2026. doi:10.1016/j.jocmr.2026.102753

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

Insights Imaging · Nov 20, 2026 · Research · Radiology & Imaging

Integrated system predicts disease-free survival in pancreatic cancer patients better

Eur Radiol Exp · Nov 20, 2026 · Meta-analysis · Radiology & Imaging, Oncology

MRI radiomics of pancreatic tumours: a systematic review of methodological quality and imaging reproducibility

Insights Imaging · Nov 19, 2026 · Research · Radiology & Imaging

Dual-phase photon-counting detector localized parathyroid adenomas with 67.3% to 83.7% sensitivity

EJNMMI Res · Nov 19, 2026 · Research · Radiology & Imaging

Small language model pipeline structures clinical information for dopamine transporter SPECT imaging reports

Insights Imaging · Nov 18, 2026 · Research · Radiology & Imaging

MRI detected placenta accreta spectrum with 100 percent sensitivity