Reliability of Hepatic Steatosis Quantification by Controlled Attenuation Parameter in Steatotic Liver Disease

Simonis L, Marcour Y, Embacher J, Hruska P, Andersen P, Mehl B, et al
Gastroenterology & HepatologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Background & aims Assessment of hepatic steatosis is key for diagnosis and monitoring of steatotic liver disease. Controlled attenuation parameter is widely used, but concerns regarding its measurement variability exist. We evaluated the repeatability and reproducibility of controlled attenuation parameter and FibroScan-aspartate aminotransferase score across different clinical steatotic liver disease settings and disease stages. Methods We assessed same-day repeatability in subjects with suspected steatotic liver disease in secondary care (cohort I, n = 40) and tertiary care (cohort II, n = 58). Different-day reproducibility within 28 days was assessed in 4 cohorts: suspected steatotic liver disease (cohort III, n = 37), suspected fibrosis (cohort IV, n = 163), compensated advanced steatotic liver disease (cohort V, n = 32), and clinically significant portal hypertension (cohort VI, n = 28). Agreement was evaluated using the intraclass correlation coefficient, Bland-Altman analysis, and minimal detectable change. Categorical agreement was assessed by observed agreement and Cohen's Kappa. Results Same-day controlled attenuation parameter agreement was moderate to good (intraclass correlation coefficient, 0.64-0.80), but variability was substantial, with a minimal detectable change of 57 to 69 dB/m, corresponding to a relative minimal detectable change of 18% to 25%. Agreement for dichotomized controlled attenuation parameter cutoffs was moderate to strong (Cohen's Kappa = 0.33-0.65). Across different days, controlled attenuation parameter reproducibility was lower and worsened with disease severity. Intraclass correlation coefficients ranged from 0.44 to 0.67 in cohorts with suspected steatotic liver disease/fibrosis, decreased to 0.52 in compensated advanced steatotic liver disease, and was poor in clinically significant portal hypertension. Correspondingly, minimal detectable change increased from 80 to 94 dB/m (26%-34%) in less advanced disease to 128 to 174 dB/m (49%-72%) in advanced disease. FibroScan-aspartate aminotransferase score showed higher reproducibility in cohorts III to V (intraclass correlation coefficient, 0.73-0.82; minimal detectable change, 0.19-0.33) but also declined in cohort VI (intraclass correlation coefficient, 0.54). Conclusions The minimal detectable change of controlled attenuation parameter is >57 to 69 dB/m (>18%-25%) and substantially greater in a longitudinal setting and advanced disease.

DOI: 10.1016/j.cgh.2026.05.006 · PubMed: 42128040

Spotted a mistake? Suggest a correction

More in Gastroenterology & Hepatology

JHEP Rep · Nov 21, 2026 · Research · Gastroenterology & Hepatology

Low public awareness of liver cancer risk factors found in survey

JHEP Rep · Nov 21, 2026 · Research · Gastroenterology & Hepatology

Pre-emptive TIPS reduces further decompensation after gastric variceal hemorrhage

JHEP Rep · Nov 21, 2026 · Research · Gastroenterology & Hepatology

Tenofovir associated with lower hepatocellular carcinoma risk than entecavir

Gut Microbes · Nov 21, 2026 · Randomized trial · Gastroenterology & Hepatology Visual abstract

Antibiotic effects on gut-derived short chain fatty acid pools in healthy volunteers

Hepatol Commun · Nov 20, 2026 · Meta-analysis · Gastroenterology & Hepatology Visual abstract

Liver stiffness decreased by 2.76 kPa after 56 days of alcohol abstinence