Pulse pressure variation and stroke volume variation show moderate accuracy for predicting fluid responsiveness in surgery
Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression
Clinical question: How reliable are pulse pressure variation and stroke volume variation for predicting fluid responsiveness?
Why it matters: It is unknown how factors like patient position, anesthesia type, or fluid characteristics affect the reliability of pulse pressure variation and stroke volume variation in the operating room.
- Researchers analyzed 59 studies involving 2,947 adult surgical patients to evaluate pulse pressure variation and stroke volume variation.
- The pooled area under the curve was 0.77 for pulse pressure variation and 0.76 for stroke volume variation.
- A high tidal volume and the use of colloids were associated with better performance for pulse pressure variation.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Messina A, Caporale M, Calabrò L, Lionetti G, Bono D, Matronola GM. Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression. Crit Care. 2023. doi:10.1186/s13054-023-04706-0