Visual abstractsVisuals
ResearchEuropean Radiology · May 2, 2026

Rule-based semi-automated method to segment black hole multiple sclerosis lesions on post-gadolinium 2D T1-weighted brain images

Mattiesing RM, Groeneveld FA, Brouwer I, van Schijndel RA, Barkhof F, Mutsaerts HJMM, et al
Radiology & ImagingAdult
Read the full paper free at PubMed Central ↗

Abstract

Objectives To develop a semi-automated method to segment "black hole" lesions on post-gadolinium 2D T1-weighted images (GdT1) in multiple sclerosis (MS) that follows radiological intensity rules and perform multi-center validation. Materials and methods Multi-center spin-echo GdT1 images and accompanying proton-density (PD)/T2-weighted images and manual T2 lesion masks of the REFLEXION study (NCT00813709) of suspected/early MS were used. Briefly, the proposed method segments cortical gray matter (GM) to derive a T1-weighted intensity threshold, which is applied inside co-registered T2 lesion masks to segment black hole lesion voxels. It was optimized on a training set (N = 40, 57.5% female, mean age 31.4 ± 8.7 (standard deviation) years), and 274 patients formed the test set (61.3% female, age 31.8 ± 8.4 years). Performance was quantified by the Dice similarity coefficient (DSC) and the intraclass correlation coefficient (ICC) for absolute agreement with manual segmentations. Lesion-wise sensitivity and specificity were calculated. Results Optimization resulted in: (1) GM selection as minimally 0.8 total WM plus GM partial volume, masked by MNI cortex; (2) normalized mutual information-driven linear co-registration of T2 to GdT1 images, interpolating T2 lesion masks using trilinear interpolation and 0.6 threshold; (3) mean intensity inside GM mask used as upper intensity threshold. The optimized method had acceptable spatial accuracy (DSC: 0.39 ± 0.26) and good volumetric accuracy (ICC: 0.84, 95% CI [0.72, 0.90]. Lesion-wise sensitivity was 0.91 ± 0.19, and lesion-wise specificity was 0.62 ± 0.22. Conclusion The proposed method to semi-automatically segment black holes from post-gadolinium T1-weighted images shows acceptable performance. As a potential aid to radiologists, the method is not recommended to be used entirely without human intervention. Key points Question T1-hypointense "black hole" lesions reflect disease severity in multiple sclerosis but are not routinely quantified due to a lack of reliable analysis methods. Findings A rule-based semi-automated method for GdT1 "black hole" lesion segmentation was developed and optimized, and then validated in a large unseen multi-center test set. Clinical relevance This method adds quantitative information about GdT1 "black hole" lesions to the radiological assessment of multiple sclerosis disease severity, when false positives are manually removed. This can enhance the characterization of individual patients and advance the understanding of the disease.

Topics

Humans; Female; Multiple Sclerosis; Magnetic Resonance Imaging; Sensitivity and Specificity; Adult; Brain; Male; Gadolinium; Contrast Media; Reproducibility of Results; Image Interpretation, Computer-Assisted

DOI: 10.1007/s00330-026-12577-6 · PubMed: 42069957 · Registered: NCT00813709

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging

Integrated prognostic system predicts disease-free survival in pancreatic cancer patients

Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment

ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging

Dual-phase photon-counting CT localized parathyroid adenomas with 67.3% to 83.7% sensitivity

Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Advancing placenta accreta spectrum diagnosis: is 3-T MRI or combined MRI with ultrasound the answer?

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Classic imaging signs aid diagnosis in head and neck radiology

Classic signs in head and neck imaging-a quick guide for the radiology resident

ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging

Automated carotid plaque quantification helps identify obstructive coronary artery disease

Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease