Cyanoacrylate glue plus suture reduced umbilical venous catheter dislodgement compared to suture alone
Securement of Umbilical Venous Catheter Using Cyanoacrylate Glue: A Randomized Controlled Trial
Randomized, controlled, nonblinded trialBenefit found
Does cyanoacrylate glue reduce umbilical venous catheter dislodgement?
Who
Infants requiring an umbilical venous catheter with a centrally located tip · Single-center
Compared
7.7%Cyanoacrylate glue plus cord-anchored suture
24.6%Suture alone
Main outcome
Dislodgement of the external tract of the catheter
Bottom line: Cyanoacrylate glue plus suture is effective in decreasing umbilical venous catheter dislodgement compared to suture alone.
J Pediatr · 2023-05-26 · Save PNG
Clinical question: Does cyanoacrylate glue reduce umbilical venous catheter dislodgement?
Key points
- Researchers conducted a single-center randomized trial of infants requiring an umbilical venous catheter, which is a tube placed in a newborn's vein through the umbilical cord.
- In the first 48 hours, dislodgement was 23.1% in the suture-only group compared to 1.5% in the glue and suture group.
- The overall dislodgement rate was 24.6% for the suture-only group versus 7.7% for the glue and suture group, with no differences in infection or blood clot rates.
Limitation the authors note: This was a single-center, nonblinded trial.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Headline, design, result, key points, caveat and citation as plain text.
Cite this article
D'Andrea V, Prontera G, Pinna G, et al. Securement of Umbilical Venous Catheter Using Cyanoacrylate Glue: A Randomized Controlled Trial. J Pediatr. 2023;260:113517. doi:10.1016/j.jpeds.2023.113517
Spotted a mistake? Suggest a correction