Visual abstractsVisuals
ResearchEJNMMI Research · May 22, 2026

Simultaneous partial volume correction and denoising of brain PET images, using transformers and transfer learning

Kaviani S, Sanaat A, Mokri M, Zaidi H, Carrier JF
Radiology & ImagingNeurologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Positron emission tomography (PET) is a key tool for quantitative brain imaging, but its image quality and quantitative reliability are strongly dependent on injected radiotracer activity and acquisition time. Reducing injected dose or acquisition time lowers radiation exposure but increases image noise, while partial volume effects (PVE) further degrade signal accuracy, especially in cortical regions critical for neurodegenerative disease assessment. Conventional partial volume correction (PVC) methods such as Iterative Yang can improve quantification but are highly sensitive to noise and perform poorly in low count settings, while also relying on accurate anatomical information, typically derived from MRI, which may be unavailable, misregistered, or impractical in routine clinical workflows; in parallel, most deep learning (DL) approaches reported to date focus mainly on denoising and do not jointly address PVE. A method capable of simultaneously mitigating low count noise and PVE is needed. This study aimed to evaluate whether a DL approach can generate full count, PVC brain PET images from fast or low count non PVC scans, using both clinical and phantom datasets. Results Using clinical and phantom brain PET datasets with 18F-FDG and 18F-Florbetapir, we compared low count PET images at 10% of full counts with images processed by Iterative Yang PVC and a Swin Unetr based DL-PVC model. The DL-PVC method consistently outperformed low count non-PVC PET across all evaluations. It achieved higher structural similarity index (SSIM) by about 2%, higher peak signal to noise ratio (PSNR) by about 11%, and lower relative root mean square error (rRMSE) by about 4%, indicating improved image quality and quantitative accuracy. In the clinical test sets, DL-PVC further showed clear gains for both tracers, with SSIM improvements of 2.1% for 18F-FDG and 2% for 18F-Florbetapir, PSNR increases of 21.6% and 22.3% respectively, and substantial rRMSE reductions of 50% for 18F-FDG and 44% for 18F-Florbetapir. Conclusions Our study introduced a DL based PVC method based on Transformer and Unet architectures. By combining phantom and clinical data through a transfer learning strategy, the network benefits from the phantom ground truth activity maps while also learning the complexities present in real clinical PET. With this approach, it improves PET image quality and quantitative agreement with a high count reference, and at inference it requires only PET input, so it can be deployed without MR images for PVC.

DOI: 10.1186/s13550-026-01448-2 · PubMed: 42171947

Cite this article

Kaviani S, Sanaat A, Mokri M, Zaidi H, Carrier JF. Simultaneous partial volume correction and denoising of brain PET images, using transformers and transfer learning. EJNMMI Res. 2026. doi:10.1186/s13550-026-01448-2

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

Insights Imaging · Nov 20, 2026 · Research · Radiology & Imaging

Integrated system predicts disease-free survival in pancreatic cancer patients better

Eur Radiol Exp · Nov 20, 2026 · Meta-analysis · Radiology & Imaging, Oncology

MRI radiomics of pancreatic tumours: a systematic review of methodological quality and imaging reproducibility

Insights Imaging · Nov 19, 2026 · Research · Radiology & Imaging

Dual-phase photon-counting detector localized parathyroid adenomas with 67.3% to 83.7% sensitivity

EJNMMI Res · Nov 19, 2026 · Research · Radiology & Imaging

Small language model pipeline structures clinical information for dopamine transporter SPECT imaging reports

Insights Imaging · Nov 18, 2026 · Research · Radiology & Imaging

MRI detected placenta accreta spectrum with 100 percent sensitivity