Artificial intelligence performed as well as or better than radiologists in breast cancer screening
Standalone AI for Breast Cancer Detection at Screening Digital Mammography and Digital Breast Tomosynthesis: A Systematic Review and Meta-Analysis
Clinical question: What is the standalone performance of artificial intelligence for digital mammography and digital breast tomosynthesis?
Why it matters: The performance of artificial intelligence systems for independent interpretation of digital mammography and digital breast tomosynthesis remains to be critically evaluated.
- Researchers analyzed 16 studies involving 1,108,328 examinations in 497,091 women to compare artificial intelligence with radiologists.
- In six reader studies using digital mammography, artificial intelligence had a higher area under the receiver operating characteristic curve than radiologists (0.87 vs 0.81).
- For digital breast tomosynthesis, artificial intelligence showed a higher area under the receiver operating characteristic curve than radiologists (0.90 vs 0.79).
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Yoon JH, Strand F, Baltzer PAT, Conant EF, Gilbert FJ, Lehman CD. Standalone AI for Breast Cancer Detection at Screening Digital Mammography and Digital Breast Tomosynthesis: A Systematic Review and Meta-Analysis. Radiology. 2023. doi:10.1148/radiol.222639
Spotted a mistake? Suggest a correction
The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.
Get the weekly digest