Visual abstractsVisuals
ResearchJournal of Cardiovascular Magnetic Resonance · Jun 8, 2026

Transformer networks enable fast and robust dictionary generation for multiparametric cardiac mapping with variable timing

Calarnou P, George A, Georgantas C, Rocca A, Paffi G, Ogier AC, et al
Radiology & ImagingCardiologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Cardiac multiparametric mapping often relies on dictionary matching. When the acquisition timing varies due to electrocardiographic or navigator gating, dictionaries must be simulated for each acquisition, which is time-consuming and limits their in-line clinical utility. Deep learning can be used to accelerate this dictionary generation. In this work, we implement and evaluate a transformer network that leverages self-attention to capture long-range dependencies and compare its performance against a previously proposed fully connected multi-layer perceptron (FC-MLP). Methods Transformer (6 layers, 700,674 trainable parameters) and FC-MLP (3 hidden layers, 300-300-75 units) networks were implemented, optimized, and trained on synthetic timing intervals generated through extended phase graph (EPG) simulation. Network performance was quantified as mean average percent error (MAPE) versus EPG simulations in silico, as a correlation in a mapping phantom and through Bland-Atman analysis in 138 patients (age 67±13 y, 50 F) at 3T. Inference time was recorded. Finally, the full mapping pipeline was integrated directly on the MR (magnetic resonance) scanner. Results EPG dictionary simulations required 30±2 minutes per subject, whereas the transformer completed inference in 13.2±0.4 s on CPU and 89.2±0.4 ms on GPU, representing a >100-fold acceleration. In the phantom experiments, the transformer achieved near-ideal correlation with the EPG dictionary (slope 1.00 vs 1.02 for FC-MLP) and demonstrated superior accuracy in Bland-Altman analysis, with smaller bias (1.8 ms vs 13.6 ms) and narrower limits of agreement. Across patient datasets, the transformer exhibited tighter error distributions for T1 and T2 (median MAPE [IQR]: 0.37%[0.09%-0.76%] and 0.50%[0.25%-0.91%] compared to FC-MLP (2.04%[1.61%-2.55%] and 3.03%[2.40%-3.92%], p<3×10⁻¹⁷² for both), respectively. Correlation between navigator skips and MAPE was also lower for the transformer, indicating greater robustness. In vivo transformer-dictionary maps were visually indistinguishable from EPG-dictionary maps. Bland-Altman analysis in the myocardium confirmed very small biases for the transformer-dictionary maps (-1.70ms for T1, 0.23 ms for T2) versus substantially larger errors for FC-MLP-dictionary maps (18.41 ms for T1, 1.16 ms for T2). Conclusions The transformer network significantly accelerates cardiac multiparametric map reconstruction while maintaining accuracy comparable to EPG simulations and superior to the FC‑MLP. Its robustness to variable acquisition timing and minimal bias support clinical feasibility, and successful on‑scanner integration demonstrates the potential for routine in‑line deployment of quantitative T1-T2 mapping.

DOI: 10.1016/j.jocmr.2026.102757 · PubMed: 42264305

Cite this article

Calarnou P, George A, Georgantas C, Rocca A, Paffi G, Ogier AC. Transformer networks enable fast and robust dictionary generation for multiparametric cardiac mapping with variable timing. J Cardiovasc Magn Reson. 2026. doi:10.1016/j.jocmr.2026.102757

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

Insights Imaging · Nov 20, 2026 · Research · Radiology & Imaging

Integrated system predicts disease-free survival in pancreatic cancer patients better

Eur Radiol Exp · Nov 20, 2026 · Meta-analysis · Radiology & Imaging, Oncology

MRI radiomics of pancreatic tumours: a systematic review of methodological quality and imaging reproducibility

Insights Imaging · Nov 19, 2026 · Research · Radiology & Imaging

Dual-phase photon-counting detector localized parathyroid adenomas with 67.3% to 83.7% sensitivity

EJNMMI Res · Nov 19, 2026 · Research · Radiology & Imaging

Small language model pipeline structures clinical information for dopamine transporter SPECT imaging reports

Insights Imaging · Nov 18, 2026 · Research · Radiology & Imaging

MRI detected placenta accreta spectrum with 100 percent sensitivity