Fixed pressure devices were associated with better respiratory outcomes during newborn resuscitation than hand driven devices
Ventilation devices for neonatal resuscitation at birth: A systematic review and meta-analysis
Why it matters: It is unknown whether fixed pressure devices or hand driven pressure devices provide better clinical outcomes for newborns receiving respiratory support during resuscitation.
- Researchers analyzed nine studies involving 3621 newborns to compare fixed pressure devices, such as T-pieces, against hand driven pressure devices, such as self-inflating bags.
- In five randomized controlled trials, fixed pressure devices were associated with lower rates of bronchopulmonary dysplasia (RR0,68[0,48-0,96]), intubation in the delivery room (RR0,72[0,58-0,88]), and mechanical ventilation needs (RR0,81[0,67-0,96]).
- The overall analysis showed fixed pressure devices were associated with lower mortality (OR0,57[0,47-0,69]) and lower risk of cystic periventricular leukomalacia (OR0.59[0.41-0.85]), while pneumothorax rates were similar (OR0.82[0.44-1.52]).
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Tribolet S, Hennuy N, Rigo V. Ventilation devices for neonatal resuscitation at birth: A systematic review and meta-analysis. Resuscitation. 2023. doi:10.1016/j.resuscitation.2022.109681