Visual abstractsVisuals
Clinical trialNew England Journal of Medicine · May 18, 2024

A Modular Communicative Leadless Pacing-Defibrillator System

Knops RE, Lloyd MS, Roberts PR, Wright DJ, Boersma LVA, Doshi R, et al
CardiologyAdult
Read the full paper free at the publisher ↗

Abstract

Background The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. Methods We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). Results We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. Conclusions The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

Topics

Aged; Female; Humans; Male; Middle Aged; Bradycardia; Cardiac Pacing, Artificial; Death, Sudden, Cardiac; Defibrillators, Implantable; Equipment Design; Follow-Up Studies; Pacemaker, Artificial

DOI: 10.1056/NEJMoa2401807 · PubMed: 38767244 · Registered: NCT04798768

Cite this article

Knops RE, Lloyd MS, Roberts PR, Wright DJ, Boersma LVA, Doshi R. A Modular Communicative Leadless Pacing-Defibrillator System. NEJM. 2024. doi:10.1056/NEJMoa2401807

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Ann Clin Transl Neurol · Dec 18, 2025 · Research · Pediatric · Neurology

Life-Threatening Bradycardia in Anti-NMDA-Receptor Encephalitis and a Novel Use for Permanent Pacing

J Am Heart Assoc · Sep 18, 2026 · Research · Cardiology

Multicenter Study of the Electrical Characteristics and Short-Term Outcomes of the Aveir VR Leadless Pacemaker

JAMA · Oct 3, 2024 · Randomized trial · Cardiology

Assessment of Antitachycardia Pacing in Primary Prevention Patients: The APPRAISE ATP Randomized Clinical Trial

J Am Heart Assoc · Dec 17, 2025 · Research · Basic science · Cardiology

ECG-Capable Smartwatches Can Induce Magnet Mode in Cardiac Implantable Electronic Devices

Circulation · Aug 25, 2026 · Research · Cardiology

International Experience With Implantable Cardioverter Defibrillators for the Prevention of Sudden Death in High-Risk Patients With Hypertrophic Cardiomyopathy