ReviewResuscitation · Jul 23, 2026

Advanced hemodynamic monitoring during post-resuscitation care after out-of-hospital cardiac arrest: a scoping review

Grand J, Lau FF, Hassager C, Bro-Jeppesen J, Møller JE, Jakobsen JC, et al
Critical CareCardiologyEmergency MedicineAdult
Read the full paper free at the publisher ↗

Abstract

Aim Advanced hemodynamic monitoring may provide clinical information during early post-resuscitation care after out-of-hospital cardiac arrest (OHCA), but practices, treatment targets, and responses to abnormal values remain incompletely defined. We aimed to map the available evidence on advanced hemodynamic monitoring after OHCA. Methods We conducted a scoping review in accordance with a prespecified protocol and the PRISMA-ScR methodology. Eligible studies included hospitalized adults after OHCA and reported advanced hemodynamic variables beyond routine arterial blood pressure monitoring. We extracted data on study design, population, monitoring modality, variables assessed, hemodynamic targets or thresholds, treatment approaches, and reported associations with clinical outcomes. Results Twenty-eight studies were included. The most frequently reported hemodynamic variables were cardiac output (27/28 studies), mean arterial pressure (MAP, 25/28), central venous pressure (17/28), and mixed venous oxygen saturation (SvO2, 14/28), whereas pulmonary vascular variables and pulmonary capillary wedge pressure were less commonly studied. Monitoring was predominantly invasive and most often based on pulmonary artery catheterization. Prognostic associations were heterogeneous: cardiac output showed inconsistent associations with outcomes, whereas low SvO2 and elevated pulmonary artery pressure were associated with worse outcomes in some studies. Hemodynamic targets were variably defined and were most frequently related to MAP-targets. Conclusions Advanced hemodynamic monitoring after OHCA remains heterogeneous, with a focus mainly on MAP and cardiac output. No single variable was consistently associated with prognosis or treatment response, although low SvO2 and elevated pulmonary artery pressure were associated with worse outcomes. Future studies should evaluate strategies integrating multiple hemodynamic variables and individualized patient-centered hemodynamic targets.

More on this topic

Cardiac arrest and resuscitation

Subject terms

Humans; Cardiac Output; Cardiopulmonary Resuscitation; Hemodynamic Monitoring; Hemodynamics; Monitoring, Physiologic; Out-of-Hospital Cardiac Arrest

DOI: 10.1016/j.resuscitation.2026.111218 · PubMed: 42492620

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Grand J, Lau FF, Hassager C, et al. Advanced hemodynamic monitoring during post-resuscitation care after out-of-hospital cardiac arrest: a scoping review. Resuscitation. 2026;226:111218. doi:10.1016/j.resuscitation.2026.111218

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Critical Care studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Secondary analysis of a trial n = 789 · J Am Heart Assoc · Dec 20, 2024 · Cardiology, Critical Care

Higher SCAI shock classification was associated with increased 1-year mortality in comatose cardiac arrest patients

Systematic review n = 1,350 · JACC · Feb 8, 2024 · Cardiology

Implantable hemodynamic monitors were associated with lower mortality and fewer hospitalizations in heart failure patients

Systematic review n = 6,086 · Crit Care · Jun 21, 2022 · Critical Care

Fluid challenge methods in intensive care changed between 2000 and 2021

Randomized trial n = 55 · Intensive Care Med · Oct 17, 2024 · Critical Care, Nephrology

Hemodynamic monitoring allowed more fluid removal during kidney replacement therapy for patients on vasopressors

Secondary analysis of a trial n = 42 · Crit Care · Mar 23, 2025 · Critical Care

Non-invasive monitors for detecting low blood volume may depend on the type of infusion fluid used