Visual abstractsVisuals
Randomized trialThe Lancet Global Health · Feb 1, 2025

Automated oxygen control for preterm infants receiving continuous positive airway pressure in southwest Nigeria: an open-label, randomised, crossover trial

Subhi R, McLeod L, Ayede AI, Dedeke IO, Risikat Q, Akanbi AR, et al
Public & Global HealthPediatricsPulmonologyPediatric
Read the full paper free at the publisher ↗

Abstract

Background Titration of oxygen therapy to target safe oxygen saturation (SpO2) values is a vital part of care for preterm infants, but is difficult to achieve, particularly in settings in which oxygen, monitoring technology, and human resources are scarce. We aimed to evaluate the safety and efficacy of automated titration of oxygen therapy partnered with a low-cost continuous positive airway pressure (CPAP) device versus manual oxygen control in preterm infants requiring CPAP in a high-mortality, low-resource setting. Methods In this open-label, randomised, crossover trial, preterm infants with a gestational age younger than 34 weeks (or a birthweight <2 kg if gestation was unknown) who were aged 12 h or older and required CPAP and oxygen were recruited at two hospitals in southwest Nigeria. Participants were randomly assigned (1:1) to one of two intervention sequences (ie, to commence the study on automated oxygen control or manual oxygen control) with block randomisation (blocks of 4 and 6) and stratification by health facility. The study statistician was masked to treatment group assignment, but the participants' parents or caregivers and clinical staff were not. Participants received automated or manual oxygen control for two 24-h periods in random sequence. Automated oxygen titration was done with a control algorithm with proven efficacy in high-resource settings. During periods of manual control, oxygen therapy was adjusted by clinicians. The primary outcome was the adjusted mean difference in the proportion of time participants spent in the SpO2 target range (ie, SpO2 91-95% when receiving oxygen or SpO2 91-100% when not receiving oxygen) between automated and manual oxygen control, analysed by intention to treat with weighted repeated measures mixed model linear regression. This trial is registered with ClinicalTrials.gov, NCT05508308, and is completed. Findings Between Sept 13, 2022, and Sept 11, 2023, 72 infants were screened, and 49 (22 female, 27 male; median gestation 29 weeks [IQR 28-31]; median birthweight 1·2 kg [1·1-1·5]) were enrolled in the study and randomly assigned. A total of 80 study periods for 46 infants contributed data to the analysis of the primary outcome as three (6%) of the 49 participants had no oxygenation data from either study period. The mean proportion of time spent in the SpO2 target range was higher during automated control periods than during periods of manual control (adjusted mean 88·1% [95% CI 84·0-92·2] vs 30·1% [20·9-39·3]; adjusted mean difference 58·0% [95% CI 48·0-67·9]; p<0·0001). There were no device-related adverse patient outcomes and short-term safety outcomes favoured automated control. Interpretation Automated titration of oxygen partnered with a low-cost CPAP device improved time spent in the safe SpO2 range compared with manual control. There is high potential for this technology to mitigate the risk of oxygen-mediated complications in preterm infants in low-resource settings. Funding National Health and Medical Research Council Australia and University of Tasmania.

Abstract reproduced under the article’s CC BY licence.

Topics

Female; Humans; Infant, Newborn; Male; Automation; Continuous Positive Airway Pressure; Cross-Over Studies; Infant, Premature; Nigeria; Oxygen; Oxygen Inhalation Therapy; Oxygen Saturation

DOI: 10.1016/S2214-109X(24)00458-3 · PubMed: 39890225 · Registered: NCT05508308

Cite this article

Subhi R, McLeod L, Ayede AI, Dedeke IO, Risikat Q, Akanbi AR. Automated oxygen control for preterm infants receiving continuous positive airway pressure in southwest Nigeria: an open-label, randomised, crossover trial. Lancet Glob Health. 2025. doi:10.1016/S2214-109X(24)00458-3

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

BMJ Open Respir Res · Jun 18, 2024 · Randomized trial · Pulmonology, Cardiology

Automated oxygen titration with non-invasive ventilation in hypoxaemic adults with cardiorespiratory disease: a randomised cross-over trial

BMJ Paediatr Open · May 14, 2025 · Randomized trial · Pediatric · Pediatrics, Pulmonology

Automated oxygen control in preterm babies on respiratory support: protocol for a randomised crossover trial

BMJ Paediatr Open · Feb 12, 2025 · Randomized trial · Pediatric · Pediatrics, Pulmonology

Targeted oxygenation in the respiratory care of premature infants at delivery-effects on outcome: a randomised controlled trial (Torpido 3060) study protocol

JAMA Pediatr · Jun 24, 2024 · Meta-analysis · Pediatric · Pediatrics, Critical Care

Initial Oxygen Concentration for the Resuscitation of Infants Born at Less Than 32 Weeks' Gestation: A Systematic Review and Individual Participant Data Network Meta-Analysis

BMJ Paediatr Open · Jul 16, 2024 · Randomized trial · Pediatric · Pediatrics

Performance and safety of the PRICO closed-loop oxygen saturation targeting system in neonates: pragmatic multicentre cross-over study (TarOx Study)