ResearchJournal of Cardiovascular Magnetic Resonance · Jan 14, 2026

Cardiovascular magnetic resonance-derived metrics as diagnostic markers for left ventricular outflow tract obstruction in hypertrophic cardiomyopathy

Alexandridis GM, Schoonvelde SAC, Koppelaar AJ, Zwetsloot PP, Budde RPJ, Kardys I, et al
Radiology & ImagingCardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background This study aims to assess the utility of cardiovascular magnetic resonance (CMR)-derived measurements as diagnostic indicators for left ventricular outflow tract obstruction (LVOTO) in hypertrophic cardiomyopathy (HCM) patients, using Doppler echocardiography as the reference method. Methods In this single-center retrospective cross-sectional study, adult HCM patients with transthoracic echocardiography and CMR within a 6-month time window were enrolled. Doppler LVOT gradient was measured both at rest and under provocative maneuvers. LVOTO was defined as a gradient ≥30 mmHg. The total cohort was randomly divided into a training (80%) and validation (20%) cohorts, maintaining the same proportions of patients with and without LVOTO in both cohorts. In CMR, all measurements were performed in the three-chamber balanced steady-state free precession cine images. CMR metrics were examined in relation to LVOTO by means of multivariable logistic regression models. Results Four hundred forty-eight adult HCM patients (67% (301/448) males, median (25th-75th percentile) age 55 (45-62) years) were enrolled. LVOTO was present in 42% (186/448) HCM patients. For identifying LVOTO, a model including the minimum distance between the mitral leaflet tip and the interventricular septum indexed to body surface area (minimum MV-IVSi distance), left ventricular (LV) stroke volume, and signal intensity ratio LVOT/LV showed an outstanding discriminatory ability in the validation cohort with an area under the curve (AUC) of 0.91 (95% confidence interval (CI) 0.85-0.97). The univariable model of the minimum MV-IVSi distance showed an AUC of 0.88 (95%CI 0.81-0.95). An MV-IVSi distance ≤6.5 mm/m2 yielded a specificity of 94% and a positive predictive value of 89%, and >9.0 mm/m2, a sensitivity of 97% and a negative predictive value of 97%. The minimum MV-IVSi distance showed excellent intra- and inter-observer reproducibility with an intraclass correlation coefficient of ≥0.95. Conclusion CMR-derived parameters, particularly the minimum MV-IVSi distance, can accurately identify LVOTO in HCM patients and easily be integrated into a standard CMR analysis.

Subject terms

Humans; Ventricular Outflow Obstruction, Left; Cardiomyopathy, Hypertrophic; Predictive Value of Tests; Middle Aged; Female; Magnetic Resonance Imaging, Cine; Male; Retrospective Studies; Cross-Sectional Studies; Reproducibility of Results; Echocardiography, Doppler

DOI: 10.1016/j.jocmr.2026.102691 · PubMed: 41544947

Cite this article

Alexandridis GM, Schoonvelde SAC, Koppelaar AJ, Zwetsloot PP, Budde RPJ, Kardys I. Cardiovascular magnetic resonance-derived metrics as diagnostic markers for left ventricular outflow tract obstruction in hypertrophic cardiomyopathy. J Cardiovasc Magn Reson. 2026. doi:10.1016/j.jocmr.2026.102691

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.

Get the weekly digest

Similar articles

Research · J Am Heart Assoc · Mar 10, 2026 · Cardiology

Automated Classification of Mitral and Tricuspid Regurgitation With Explainability and Real-World Practice Experience

Research · J Cardiovasc Magn Reson · Nov 25, 2025 · Radiology & Imaging, Cardiology

Non-invasive versus invasive estimation of left ventricular wall stress with cardiac magnetic resonance imaging in severe aortic stenosis

Research · J Cardiovasc Magn Reson · Nov 24, 2025 · Radiology & Imaging, Cardiology

A multi-dynamic low-rank deep image prior for three-dimensional real-time cardiovascular magnetic resonance imaging

Research · J Cardiovasc Magn Reson · Jan 23, 2026 · Radiology & Imaging

Isotropic three-dimensional cardiac cine imaging at 0.55T using stack-of-spiral sampling and four-dimensional iterative motion compensation

Research · J Cardiovasc Magn Reson · Mar 20, 2026 · Radiology & Imaging, Cardiology

Interactive deep learning for myocardial scar segmentation using cardiovascular magnetic resonance