Visual abstractsVisuals
ResearchJournal of the American Heart Association · Mar 13, 2026

Clinical Validation of a Novel Pressure Microcatheter-Based Nonhyperemic Pressure Ratio (SUPREME II Study)

Zhou J, Yang J, Zhang W, Zu L, Cheng Y, Li M, et al
CardiologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Background The constant resistance ratio (cRR) is a novel nonhyperemic pressure ratio based on piezoresistive pressure microcatheter (PMC) measurements. With repeated measurements in randomized order of PMC and pressure wire techniques, this study aimed primarily to validate the diagnostic performance of cRR compared with fractional flow reserve (FFR) in coronary lesions of 30% to 90% diameter stenosis. Methods SUPREME II (Sensor-Equipped Ultrathin Pressure Microcatheter Versus Pressure Wire for Physiological Measurements) was a multicenter, prospective study that included 466 patients (483 vessels) from 11 centers. All target vessels were assessed using both pressure wire and PMC separately in randomized order under resting and hyperemic conditions. The primary end point was the diagnostic accuracy of the cRR using a PMC-based FFR of ≤0.80 as the reference standard. Secondary end points included the cRR "gray zone" of the cRR-FFR hybrid strategy and the proportion of patients in whom diagnosed was achieved without vasodilator use. Results The optimal cRR cutoff was 0.89, which correctly classified 82.8% of the patients, with a sensitivity and specificity of 87.0% and 80.1%, respectively, and achieved an area under the curve of 0.92 with FFRPMC as reference (area under the curve 0.90 with FFRpressure wire as reference). If FFR was added for decision-making in cases of cRR values between 0.85 and 0.91, a cRR--FFR hybrid strategy achieved a 95.3% agreement with the FFR-only strategy and allowed 68.5% of the patients to not require using vasodilator. Conclusions In coronary stenosis of 30% to 90% diameter stenosis, cRR measurements were highly feasible. The diagnostic accuracy of cRR with FFRPMC as reference was excellent. Further, a cRR-FFR hybrid strategy may reduce vasodilator use without compromising diagnostic accuracy. Registration URL: https://clinicaltrials.gov/study/NCT05417763; Unique Identifier: NCT05417763.

Topics

Humans; Fractional Flow Reserve, Myocardial; Cardiac Catheters; Cardiac Catheterization; Prospective Studies; Female; Coronary Stenosis; Male; Aged; Predictive Value of Tests; Middle Aged; Reproducibility of Results

DOI: 10.1161/JAHA.125.041920 · PubMed: 41823250 · Registered: NCT05417763

Cite this article

Zhou J, Yang J, Zhang W, Zu L, Cheng Y, Li M. Clinical Validation of a Novel Pressure Microcatheter-Based Nonhyperemic Pressure Ratio (SUPREME II Study). J Am Heart Assoc. 2026. doi:10.1161/JAHA.125.041920

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

J Am Heart Assoc · Jan 19, 2026 · Meta-analysis · Cardiology

Diagnostic Performance of Non-Hyperemic Pressure Ratios Versus Fractional Flow Reserve Stratified by Coronary Artery: A Systematic Review and Meta-Analysis of Individual Patient Data

J Am Heart Assoc · Aug 20, 2026 · Research · Cardiology

Artificial Intelligence-Driven Angiographic Quantification of Fractional Flow Reserve: Proof-of-Concept Validation Study

Circulation · Sep 22, 2026 · Research · Cardiology

Prognostic Value of Coronary Computed Tomography Angiography-Derived Fractional Flow Reserve From a Large Nationwide Cohort

JACC · Aug 28, 2026 · Randomized trial · Cardiology Visual abstract

Adding computed tomography-derived fractional flow reserve reduced unnecessary invasive heart imaging in coronary artery disease patients

BMC Med · Nov 26, 2025 · Research · Cardiology, Radiology & Imaging

Interpretable and reproducible machine learning model for coronary calcification and segment-level stenoses stratification on computed tomography angiography