ResearchResuscitation Plus · Mar 2, 2026

Defining thoracic impedance thresholds for rescue ventilation: a laboratory study

Jarrett P, Prakash R, Thakur B, Thomas J, Cao D, Chang M, et al
Emergency MedicineAdult
Read the full paper free at PubMed Central ↗

Abstract

Aim To establish evidence-based peak amplitude thresholds for thoracic bioimpedance monitoring of ventilation and characterize the relationship between peak amplitude and tidal volume across two defibrillator devices used in pre-hospital care during cardiopulmonary resuscitation. Methods Thirty healthy adults underwent mechanical ventilation while thoracic bioimpedance was monitored using LifePak12 and HeartStart MRx defibrillators at five tidal volumes (250-800 mL). Peak amplitude measurements were extracted from thoracic bioimpedance waveforms. Linear mixed-effects models accounted for repeated measurements. Sex-stratified analyses examined device-specific sensitivity differences. Breath detection thresholds were calculated at various target sensitivities. Results Linear relationships were observed for both devices. The LifePak 12 device showed tidal volume slopes of 0.0022 Ω/mL for females and 0.0013 Ω/mL for males. The HeartStart MRx device demonstrated slopes of 0.0030 Ω/mL for females and 0.0016 Ω/mL for males. Males showed 41-47% lower sensitivity to tidal volume changes than females across both devices. Model performance showed intraclass-correlations of 0.713-0.783 with prediction correlations exceeding 0.97. For the 250 mL breath, peak amplitude thresholds were 0.630/0.40 Ω (female/male) for LifePak12 and 0.45/0.30 Ω for HeartStart MRx at 90% detection sensitivity. Conclusion This study provides preliminary sex- and device-specific peak amplitude thresholds for breath identification using thoracic bioimpedance waveforms. The observed linear relationships and provided thresholds may improve categorical breath detection in resuscitation research. These findings require validation in cardiac arrest patients to ensure generalizability for clinical application.

DOI: 10.1016/j.resplu.2026.101284 · PubMed: 41859376

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Jarrett P, Prakash R, Thakur B, et al. Defining thoracic impedance thresholds for rescue ventilation: a laboratory study. Resusc Plus. 2026;28:101284. doi:10.1016/j.resplu.2026.101284

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Emergency Medicine studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

More in Emergency Medicine

Research · BMC Palliat Care · Nov 25, 2026 · Palliative Care, Emergency Medicine

Referral to specialized palliative care linked to better symptom control and shorter ED stays

Research · J Med Internet Res · Nov 24, 2026 · Digital Health & AI, Emergency Medicine

Three AI models matched four doctors in emergency triage agreement in a German hospital cohort

Systematic review · J Med Internet Res · Nov 23, 2026 · Digital Health & AI, Emergency Medicine

Large language models mainly used for documentation in emergency departments

Research · BMJ Med · Nov 18, 2026 · Emergency Medicine

Direct admission to level 1 trauma centre was linked to lower 30 day mortality

Research · Am J Emerg Med · Nov 13, 2026 · Emergency Medicine, Hematology

Emergency department blood transfusions were associated with longer stays and higher rates of return