Randomized trialJAMA Network Open · Sep 1, 2022

Effectiveness of Self-cut vs Mesh-Kit Titanium-Coated Polypropylene Mesh for Transvaginal Treatment of Severe Pelvic Organ Prolapse: A Multicenter Randomized Noninferiority Clinical Trial

Chen J, Yu J, Morse A, Tao G, Gong J, Wang B, et al
SurgeryAdult
Read the full paper free at PubMed Central ↗

Abstract

Importance Transvaginal mesh (TVM) can increase the durability of vaginal surgical procedures for pelvic organ prolapse (POP) and may be indicated in certain situations despite concerns about mesh-related complications. In addition, the expense of commercial mesh kits has limited their use. The effectiveness, safety, and cost of a self-cut mesh procedure compared with a commercial mesh-kit procedure for the surgical treatment of women with POP is unclear. Objective To assess the 1-year effectiveness and safety of self-cut titanium-coated polypropylene mesh compared with a precut commercial mesh kit for the transvaginal surgical treatment of women with severe symptomatic POP. Design, setting, and participants This multicenter randomized noninferiority clinical trial was conducted at 11 hospitals in 8 provinces of China. A total of 336 women with symptomatic stage 3 to 4 POP were enrolled between January 22, 2018, and November 11, 2019, with follow-up through December 11, 2020. Interventions Participants were randomized to receive a TVM procedure using either self-cut mesh (self-cut mesh group) or a precut commercial mesh kit (mesh-kit group), both of which used the same titanium-coated polypropylene mesh. Main outcomes and measures The primary outcome measure was composite surgical success at 1 year, which was defined as the absence of vaginal bulge symptoms, no additional retreatment for POP, and no vaginal prolapse at or beyond the hymen. Secondary outcomes included symptom-specific pelvic floor function and quality-of-life measures as well as perioperative complications, including mesh-related complications and hospitalization costs. Complications were categorized using the Clavien-Dindo system (with grade 1 indicating any deviation from the normal postoperative course but not requiring grade 2-4 interventions; grade 2, need for pharmacological treatment, blood transfusion, and/or total parenteral nutrition; grade 3, the need for surgical, endoscopic, and/or interventional radiological procedures; and grade 4, life threatening). Results Among 336 female participants (mean [SD] age, 63.3 [5.9] years; all of Chinese ethnicity), 169 patients were randomized to the self-cut mesh group, and 167 were randomized to the mesh-kit group. Three patients were unavailable for follow-up after 1 year. In the intention-to-treat analysis, 162 women (95.9%) in the self-cut mesh group had outcomes that met the definition of surgical success; this result was noninferior to the surgical success rate observed in the mesh-kit group (146 women [87.4%]; risk difference, 8.5%; 95% CI, 2.2%-14.3%; P = .006). The frequency of Clavien-Dindo grade 1 to 3 perioperative complications was not significant between groups (12 of 166 women [7.2%] in the self-cut mesh group vs 20 of 161 women [12.4%] in the mesh-kit group; P = .14). Vaginal mesh exposure rates in women examined at 1 year were similar (4 women [2.4%] in the self-cut mesh group vs 8 women [4.8%] in the mesh-kit group; P = .23). Median (IQR) total hospitalization costs were $3663.00 ($3258.90-$4495.10) in the self-cut mesh group vs $6144.00 ($5434.90-$7160.20) in the mesh-kit group (P < .01), representing savings of $2481.00 (40.4%) with the use of self-cut mesh. Conclusions and relevance In this clinical trial, the composite surgical success rate of a self-cut mesh procedure was noninferior to that of a commercial mesh-kit procedure using the same titanium-coated polypropylene mesh and reduced hospitalization expenses by 40.4%. These findings suggest that the use of self-cut mesh procedures may be advantageous for the surgical treatment of some women with severe POP, particularly those in countries with low and middle income. Trial registration ClinicalTrials.gov identifier: NCT03283124.

Topics

Female; Humans; Middle Aged; Pelvic Organ Prolapse; Polypropylenes; Surgical Mesh; Titanium; Treatment Outcome

DOI: 10.1001/jamanetworkopen.2022.31869 · PubMed: 36112377 · Registered: NCT03283124

Cite this article

Chen J, Yu J, Morse A, Tao G, Gong J, Wang B. Effectiveness of Self-cut vs Mesh-Kit Titanium-Coated Polypropylene Mesh for Transvaginal Treatment of Severe Pelvic Organ Prolapse: A Multicenter Randomized Noninferiority Clinical Trial. JAMA Netw Open. 2022. doi:10.1001/jamanetworkopen.2022.31869

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.

Get the weekly digest

Similar articles

Meta-analysis · J Plast Reconstr Aesthet Surg · Jul 29, 2024 · Plastic & Reconstructive Surgery, Surgery

Titanium-coated mesh shows comparable safety and aesthetics to biological matrices in breast reconstruction

Randomized trial · JAMA Surg · Sep 16, 2021 · Surgery

Effect of Hernia Mesh Weights on Postoperative Patient-Related and Clinical Outcomes After Open Ventral Hernia Repair: A Randomized Clinical Trial

Randomized trial · Obstet Gynecol · Apr 5, 2022 · Obstetrics & Gynecology, Surgery

Contemporary Use and Techniques of Laparoscopic Sacrocolpopexy With or Without Robotic Assistance for Pelvic Organ Prolapse

Randomized trial · JAMA Surg · May 22, 2024 · Surgery

Sacrocolpopexy and transvaginal mesh showed similar failure rates for vaginal vault prolapse repair

Randomized trial · AJOG · Feb 6, 2025 · Obstetrics & Gynecology, Surgery

Body image and sexual function improve after prolapse repair surgery